Trouble shooting
Problem
Device does not start
Low or lack of suction
Possible cause
Mains voltage is not present
The equipment is not
switched on
Safety stop due to miss-
ing or incorrectly inserted
pleated filter (
13)
Defective on/off switch
(
6)
Defective motor
The single-use thermal fuse
has disconnected the power
circuit
Suction hose (
11) or suc-
tion tube (
12) blocked
The metal container (
is not closed
The metal container (
is full
The pleated filter (
clogged
The air filter (
17) is
clogged
Fault correction
Check plug socket, power cord,
line, plug and fuse, where ap-
propriate, repair through electri-
cal specialist
Switch on the equipment (see
"switching on/off")
Insert the pleated filter correctly
(see "cleaning/maintenance")
Repair through customer service
Remove obstructions and block-
ages
10)
Close the metal container
10)
Empty the metal container (see
"cleaning/maintenance")
Clean or replace the pleated
13) is
filter (see "cleaning/mainte-
nance")
Clean the air filter (see "clean-
ing/maintenance")
GB
45