Filling
1. Screw the air hose (1h) and the device (1g) together.
2. Connect the plug nipple (1d) of the device with a compressed air
supply.
3. Put the valve connection (1e) on the tyre valve.
4. Press the trigger (6), compressed air flows into the tyre.
The moment you are filling in the air, the manometer (1a) shows a
pressure that is a little bit higher than the actual tyre pressure. When you
release the trigger, you can read the actual tyre pressure on the manome-
ter.
Deflation of Air
If the tyre pressure is too high, use the deflation button (1c) and slowly
reduce the air pressure to the desired value.
Technical Data
Pressure Range: from 0 – 10 bar
Diameter of Pressure Gauge: 6 cm
Tube Length: approx. 41 cm
Manometer Accuracy: ± 0.1 bar
Compressed Air Connection: ¼"
Cleaning and Maintenance
Do not allow foreign substances and dirt to enter the compressed air
nozzle.
Do not expose the manometer to vibrations or mechanical stress.
Add a few drops of oil to the sealing of the trigger pin in regular
intervals. Apart from that the device is maintenance free.
Storing
Store the device indoors in a dry place that is protected from dust, dirt
and extreme temperatures.
Store the device out of reach of children.
For storing the device, use the hanger (1b).