4. Installing the main or additional intercom panel

Warning:
The product must not be connected to the power supply before wiring is complete.
1
4
5
3
1
0
2
2
1
2
1
2
1 2 3 4
5 6
7 8
1
2
SMARTHOME FRANCE
5
3
1
0
2
2
19 avenue Marcel Dassault 37200 TOURS
FRANCE
20V
110mA
RFID 125kHz
IP44
7
1 - Remove the tamper-resistant screw from the intercom panel.
2 - Tip the intercom panel cover forward.
3 – The intercom's lens should be approximately 1.60m above the ground.
4 – Mark the locations.
5 - Drill.
6 - Use pegs adapted to the nature of the support (the screws supplied are suitable for
solid walls).
7 – Connect the two wires from the monitor and, if necessary, connect the electric strike
plate and the gate (see section 1. Wiring). Confi gure the switches at the back of the
intercom panel (see section 2. Confi guring the intercom).
8 – Insert the screws and refi t the two caps concealing the retaining screws.
Note:
screw through the black covers on the back of the intercom panel – do not remove
them.