22/32
Bosch Rexroth AG
General notes on damages to property and products
Dangerous electrical voltage
Under certain circumstances, compensation currents ("crossover currents"
according to EN 62135-1) may flow through the MPE protective conductor
connections. This means that human lives may be in danger in the event of an
insulation failure!
The compensation currents must generally be avoided because they may
interrupt the protective conductor connection through the protective
conductor jumper (MPE).
An interruption of the protective conductor connection will render the "direct
protective conductor connection" protective measure inoperative.
3
General notes on damages to property and
products
For general notes on damages to property and products refer to Tab. 1: Required
and supplementary documentation Rexroth PSG xxxx MF-Welding Transformers
Instructions and Rexroth PSG xxxx MF-Welding Transformers Safety and user
information.
Mechanical Load!
Non-observance may cause destruction of the transformer!
The rectifier must not be used as load-bearing part.
The secondary connections are only included for the electrical contact.
Applications have to be realized, that no forces working on the connections.
The transformer housing must not be used as load-bearing construction
element of the welding gun.
Environmental factors!
Non-observance may cause destruction of the transformer!
Storage: -25°C bis +70°C, cooling system completely emptied!
Operation: +5°C bis +40°C
R911344478 | PSG6130.00 PS/PSC
WARNING
NOTICE
NOTICE