Key considerations
• Nozzle design and nozzle location are critical to a successful application.
• Avoid reflective interference from vessel walls and obstructions by following the
Nozzle design
• Bottom edge of horn must project from nozzle.
• Nozzle must have adequate clearance to allow LR460 to be positioned at an angle (see
top clamping plate
10 mm (0.38")
285 mm
(11.22")
Nozzle location
• Locate antenna at least 1 meter away from
• Keep emission cone free of interference
• Make allowance for beam spread to avoid
Device orientation
Align the antenna so that the radar cone is
perpendicular to the surface of the monitored
material, if possible.
Easy Aimer Installation
Note:
the device is free to tilt to a maximum of 30°.
1.
2.
3.
A5E32007360
Downloaded from
www.Manualslib.com
guidelines below.
Device orientation
below).
side wall.
from ladders, pipes, I-beams or filling
streams.
interference with the emission cone.
When the Easy Aimer ball is loosened,
Holding the electronics enclosure firmly,
loosen the Easy Aimer ball locking bolts and
gently reposition the enclosure (see
design
above).
Direct SITRANS LR460 so the horn antenna
is pointed at an angle perpendicular to the material surface, if possible. (As a guide, aim
the beam at a point approximately 2/3 of the way across the tank diameter.)
When the desired position is reached, re-tighten the 5 bolts to 15-23 N m (11 to 17 Lbf-ft).
SITRANS LR460 – QUICK START MANUAL
manuals search engine
bottom
clamping plate
customer-
supplied gasket
30 °
Nozzle
Easy Aimer
ball locking
joints
min. clearance
10 mm (4")
min. 1 m (39")
Easy
Aimer
emission
cone
4" horn
3"
horn
11°
Page EN-5

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis