1.1 Language
Options
1.2 Application Type (APPL)
Options
1.3 Operation
Options
1.4 Units
Select the units for the Quick Start variables (high and low calibration point, and level, distance,
or space).
Options
1.5 High Calibration Point (CAL HIGH)
Distance from Sensor Reference to high calibration point: usually process full level (See 1.3
Operation for an illustration).
Values
1.6 Low Calibration Point (CAL LOW)
Distance from Sensor Reference to low calibration point: usually process empty level (See 1.3
Operation for an illustration)
Values
Page EN-12
Downloaded from
www.Manualslib.com
ENGLISH, DEUTSCH, FRANCAIS, ESPANOL
STEEL
Silo construction
CONCRETE
LEVEL
SPACE
DISTANCE
Operation types
sensor reference point
high
(flange face)
calibration
point
low calibration point
mm, cm, m, in, ft
Range 0.0000 to 100.00 m
.
Range: 0.0000 to 100.00 m
SITRANS LR460 – QUICK START MANUAL
manuals search engine
Distance to material surface referenced from low calibration point
(process empty level).
Distance to high calibration point (process full level) referenced
from material surface.
Distance to material surface referenced from sensor reference
point.
distance
space
level
A5E32007360