Herunterladen Inhalt Inhalt Diese Seite drucken

Changing The Ruler; Removing The Handles; Changing The Position Indicator; Applying The "Indicator" Label (1 690 382 482) - Bosch SCT 141 serie Erstinbetriebnahme

Kalibrier- und justiervorrichtungen
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

en
20 | SCT 141x | SCT 141x assembly
4.2

Changing the ruler

1. Loosen the knurled screws (Abb. 2, item 1) on the
mounts of the ruler.
2. Slide up and remove the present ruler (with a scale
starting from 1000 mm) from the DAS 800/1000
(VAS 6430).
3. Slide the ruler (1 690 382 469) from the scope of
delivery of the SCT 141x (with a scale starting from
500 mm) through the ruler mounts.
4. Use the knurled screws to secure the ruler on the
mounts.
Abb. 2:
Changing the ruler on the VAS 6430
1 Knurled screw
2 Ruler
4.3

Removing the handles

i
To attach the SCT 141x to the DAS 800/1000
(VAS 6430), the handles (Abb. 3, item 1) must be
removed.
Loosen the screws (Abb. 3, item 2) until the handles
(Abb. 3, item 1) can be slid up and out of the frame.
1
2
1
Abb. 3:
Handles in the frame on the DAS 800/1000 (VAS 6430)
1 Screws
2 Handles
|
1 690 386 065
2017-09-29
1
2
1
4.4

Changing the position indicator

4.4.1

Applying the "Indicator" label (1 690 382 482)

Apply the label to the indicator as shown in the
following figure.
1
2
3
Abb. 4:
Applying the label to the position indicator
1 "VAS SCT" position indicator
2 "SCT 1" position indicator
3 "SCT 2" position indicator
"VAS SCT" position indicator – no offset
R
Indicates the height on ground-level measurement
bays.
R
Relevant for height adjustments in the VW measure-
ment program.
R
Standard position indicator that cannot be moved or
removed.
R
The vehicle rests on the ground during calibration.
R
No offset by lift or leveling surface.
"SCT 1" position indicator – offset
R
Indicates the height on measurement bays with a lift
or leveling surface.
R
Flexible position indicator set according to the offset
value.
R
The vehicle rests on a lift or leveling surface (off the
ground).
R
The height of the lift or leveling surface is the offset
value.
R
The precision measuring bar touches the upper end
stops.
"SCT 2" position indicator – low calibration heights
R
Indicates the height for very low calibration heights
that cannot be reached by the "VAS SCT" or "SCT 1"
position indicators.
R
On measurement bays without an offset, the positi-
on indicator is set to 400 mm.
R
On measurement bays with an offset, the offset va-
lue is applied against the value of 400 mm: 400 mm
– offset value
R
The precision measuring bar touches the lower end
stops.