8.
Connect the sensor cable to the terminal connection board shown above.
9.
Secure the sensor cable with cable ties.
10. Crimp the ring terminal 4 mm (0. 1 9") to sensor earth cable.
11. Connect electronics module and terminal connection board. Be sure that all
terminals are tight.
12. Insert the electronics module into the housing. The terminal connection board is
used to guide the cable into the extension tube.
13. Fold cable as shown in diagram above.
14. Secure the electronics module as shown in diagram below.
Connect protection earth
of the enclosure to
terminal
of the
electronics module.
7ML19985FT62
electronics
module, flat
side up
3 mm (1/8") screw driver
cable ties
SITRANS LVS200 – INSTRUCTION MANUAL
Connect earth cable
of the fork to the
electronics earth
terminal.