SITRANS LVS200 is normally mounted into the vessel top for full detection, or through the
tank wall at the detection level, for full, demand, or empty detection.
Cable
Standard
extension
version
version
*
max. deviation
from vertical
max. length L
α
45º
1.2 m
>45º
0.6 m
Process Cautions
Caution:
Locate SITRANS LVS200 out of path of falling material.
or:
Protect shaft and tines from falling material.
Page EN-8
*
L
α
Cable gland faces
downward to avoid
water penetration.
4 m
SITRANS LVS200 – INSTRUCTION MANUAL
Sliding
Position tines vertically
bushing
to avoid product build-
version
up: use a 50 mm open-
end wrench to turn the
process connection
until the tine
orientation marking
faces up or down.
Protection in case of
high material loading.
Tine orientation
marking facing
sideways.
Use angle mounting for flowing
material only.
If angle mounting is required
with high material loading,
customer-supplied protection
from falling material must be in
place.
7ML19985FT62