Herunterladen Inhalt Inhalt Diese Seite drucken

LG ESS Home 10 Installationsanleitung Seite 33

Vorschau ausblenden Andere Handbücher für ESS Home 10:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

B
NOTE
y For AC cable connections, lead wire with cross-sectional area 4 mm
recommended.
y AC cable is not supplied on this product package. The system installer is responsible for
selecting proper components for the installation.
y The recommecded cable diameter for the AC cable gland is 16 mm. (including sheath)
C
12 mm
NOTE
It is recommended to use a yellow green stripe wire for the PE grounding connection.
PE
N
50 mm
Pass the AC cable through the cable
gland, rubber seal and housing as
shown in the figure.
2
or thicker is
Strip the AC cable as shown in the
figure.
1. Strip 50 mm off the AC cable.
2. Strip 12 mm off the every wires.
Installation
33
2