B
NOTE
y For battery cable connections, lead wire with cross-sectional area 4 mm
recommended.
y Battery cable is not supplied on this product package. The system installer is responsible
for selecting proper components for the installation.
C
D
15 mm
Open the spring using a screwdriver
Strip 15 mm off the both + and –
battery wires as shown in the figure.
Carefully insert the stripped wires to the
corresponding cable connector. The wire
ends have to be visible in the spring.
+ cable connector ↔ Battery wire +
– cable connector ↔ Battery wire -
And close the spring. Make sure that
the spring is snapped in.