Herunterladen Inhalt Inhalt Diese Seite drucken

Select The Best Location - Panasonic ADC0309H3E5B Installationsanleitung

Air-to-water hydromodule + tank
Vorschau ausblenden Andere Handbücher für ADC0309H3E5B:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 225
Attached accessories
No.
Accessory part
Qty. No.
Adjustable Feet
4
1
4
Reducing Adapter
1
2
5
Drain Elbow
1
3
Optional Accessories
No.
Accessories part
6
Network Adaptor (CZ-TAW1)
Dimension Diagram
598
FRONT VIEW
60
478
60
Adjustable Feet
BOTTOM VIEW
Tube Connector Function
Zone 1 Water Inlet (From Space Heating/Cooling)
a
Zone 1 Water Outlet (To Space Heating/Cooling)
b
Cold Water Inlet (Domestic Hot Water Tank)
c
Hot Water Outlet (Domestic Hot Water Tank)
d
Refrigerant Gas
e
Refrigerant Liquid
f
Domestic Hot Water Tank Discharge (Drain Tap)
g
Type: Ball Valve
Pressure Relief Valve Drainage
h
Drain Water Hole
i
Zone 2 Water Inlet (From Space Heating/Cooling)
Zone 2 Water Outlet (To Space Heating/Cooling)
Weight (kg)
Model
Capacity (L)
Empty
ADC0309H3E5B
185
124

SELECT THE BEST LOCATION

1
Install the Tank Unit in indoors with frost free weather proof
location only.
Must install on a fl at horizontal and solid hard surface.
There should not be any heat source or steam near the
Tank Unit.
A place where air circulation in the room is good.
A place where drainage can be easily done (e.g. Utility room).
A place where Tank Unit's operation noise will not cause
discomfort to the user.
Field Supply Accessories (Optional)
Accessory part
Qty.
No.
Packing
i
1
ii
Remote Controller
iii Pump
Cover
iv Outdoor sensor
1
v
vi Zone room sensor
  It is recommended to purchase the fi eld supply accessories listed in above table.
Tube Position Diagram
Qty.
1
717
e
f
h
229
159
133
102
SIDE VIEW
1
position
Connector Size
7/8-14UNF
7/16-20UNF
Rc 1/2"
Full
309
Part
Electromotoric Actuator
2-way valve kit
*Cooling model
2-port Valve
Room thermostat
Wired
Wireless
Zone water sensor
Main Components Diagram
j
k
b
d
0
8
a
e
k
i
c
c
a
d
b
o
g
475
380
300
1 Remote Controller
2 Water Pump (Zone 1)
3 Control Board Cover
4 Main PCB
5 Optional PCB
6-1
6-2
7-1
7-2
8 Heater Assembly
9 3-Way Valve
0 Overload Protector (Not Visible)
a Expansion Vessel (Not Visible)
b Air Purge Valve
c Pressure Relief Valve
427
d Flow Sensor
i
e Water Pressure Gauge
f Front Plate
g Top Plate
R 1¼"
h Right Plate
R 1¼"
i Left Plate
j Rear Plate
R ¾"
k Tank Sensor (Not Visible)
R ¾"
l Mixing Valve (Zone 2)
m Water Pump (Zone 2)
n Water Temperature Sensor (Zone 2)
o Safety Relief Valve
---
---
R 1¼"
R 1¼"
A place where Tank Unit is far from door way.
A place where accessible for maintenance.
Ensure to keep minimum distance of spaces as illustrated
below from wall, ceiling, or other obstacles.
A place where fl ammable gas leaking might not occur.
Secure the Tank Unit to prevent it being knocked over
accidentally or during earthquakes.
Model
Specifi cations Maker
SFA21/18
AC230V
VVI46/25
PAW-A2W-RTWIRED
AC230V
PAW-A2W-RTWIRELESS
Yonos 25/6
AC230V
PAW-A2W-TSOD
PAW-A2W-TSHC
PAW-A2W-TSRT
g
9
7-2
1
2
3
5
4
f
h
6-1
6-2
7-1
Single Phase RCCB/ELCB (Main Power)
Single Phase RCCB/ELCB (Backup Heater)
Water Filter Set (Zone 1)
Water Filter Set (Zone 2)
Siemens
Siemens
Wilo
n
m
l
j
3