Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 225
6. Alternative outdoor sensor
Set Yes if outdoor sensor is installed.
Controlled by optional outdoor sensor without reading the outdoor sensor of heat
pump unit.
7. External SW
Initial setting: No
Able to turn ON/OFF the operation by external switch.
8. External Error Signal
Set when external error display unit is installed.
Turn on Dry Contact SW when error happened.
(NOTE) Does not display when there is no Optional PCB.
When error occurs, error signal will be ON.
After turn off "close" from the display, error signal will still remain ON.
9. Demand control
Set when there is demand control.
Adjust terminal voltage within 1 ~ 10 V to change the operating current limit.
(NOTE) Does not display when there is no Optional PCB.
Analog input
Rate
[v]
[%]
0.0
not activate
0.1 ~ 0.6
0.7
not
10
activate
0.8
0.9 ~ 1.1
10
1.2
15
10
1.3
1.4 ~ 1.6
15
1.7
20
15
1.8
1.9 ~ 2.1
20
2.2
25
20
2.3
2.4 ~ 2.6
25
2.7
30
25
2.8
2.9 ~ 3.1
30
3.2
35
30
3.3
3.4 ~ 3.6
35
3.7
40
35
3.8
Initial setting: No
Initial setting: No
Initial setting: No
Analog input
Rate
[v]
[%]
3.9 ~ 4.1
40
4.2
45
4.3
4.4 ~ 4.6
45
4.7
50
4.8
4.9 ~ 5.1
50
5.2
55
5.3
5.4 ~ 5.6
55
5.7
60
5.8
5.9 ~ 6.1
60
6.2
65
6.3
6.4 ~ 6.6
65
6.7
70
6.8
6.9 ~ 7.1
70
7.2
75
7.3
System setup
Tank heater
Base pan heater
Alternative outdoor sensor
Select
System setup
Base pan heater
Alternative outdoor sensor
Bivalent connection
External SW
Select
System setup
Bivalent connection
External SW
External error signal
Select
System setup
External SW
External error signal
Demand control
Select
Analog input
[v]
7.4 ~ 7.6
7.7
40
80
7.8
7.9 ~ 8.1
8.2
45
85
8.3
8.4 ~ 8.6
8.7
50
90
8.8
8.9 ~ 9.1
9.2
55
95
9.3
9.4 ~ 9.6
9.7
60
100
9.8
9.9 ~
65
*A minimum operating current is applied on each model for
protection purpose.
*0.2 voltage hysteresis is provided.
*The value of voltage after 2nd decimal point are cut off.
70
Confi rm
Confi rm
Confi rm
Confi rm
Rate
[%]
75
75
80
80
85
85
90
90
95
95
100
17:26, Wed
17:26, Wed
17:26, Wed
17:26, Wed
23