3-4-7. Checking the Operating Range

After mounting the scale unit and slider, be sure to always move the machine over its entire length to check
that the machine movement range is within the scale measuring length. During this check, make sure that
LED on the interface unit does not indicate an alarm. (A/B phase output types only) Refer to section 4-2 for
removing and attaching the cover of the interface unit.
Be careful that the scale movement range does not exceed the scale measuring length + range of movement.
If it does, the scale can be damaged.

3-4-8. Securing the Head Cable

Secure the head cable with a cable clamp so that it does not get in the way of movement or operation.
The cable clamps are secured using a M4 x 10 hex. socket-head cap screw.
Note that the wiring should be made to allow enough room for machine movement during operation.
BL55-RU
Level alarm
Speed alarm
Fig. 3-15
Cable clamp (supplied)
Secure with M4 x 10 hex. socket-head cap screw
Fig. 3-16
3-11
(E)