9. Troubleshooting guide

Warning: Switch off the motor and actuate the locking brake before making any checks or adjustments.
Warning: If, after making an adjustment or repair to the engine, you let it run for a few minutes, remem-
ber that the exhaust and other parts will get hot. Do not touch these parts as they may burn you.
Fault
Poor clearing result
Poor advance
The reprinting or reproduction by any other means, in whole or in part, of documentation and papers
accompanying the products is strictly subject to the express consent of iSC GmbH.
Subject to technical changes
Possible cause
- Clearing bar defective
- Skids set too high
- Clearing bar jams on the ground
- Too much snow
- Defect on the based unit
GB
- Replace clearing bar
- Adjust skids
- Adjust skids
- Reduce the clearing width
- See troubleshooting information for
the base unit
- 16 -
Remedy