DE 09200
Voltage V
Formula: cold water inlet temperature + flow at switch on = hot water outlet temperature
Example: For 220 V / 8.0 kW and 3.7 l/min
15 ºC + 30.6 K = 45.6 ºC
DE 09200
Voltage V
Formula: cold water inlet temperature + temperature increase (at l/min) = hot water outlet temperature
Example: For 220 V / 8.0 kW and 3.2 l/min
15 ºC + 35.3 K = 50.6 ºC

Cleaning and care

S
Wipe the outside of the appliance using a mild detergent.
S
Do not use a scourer or corrosive cleaning product.
S
Clean the shower head of deposits and limescale regularly.
After sales maintenance
To prevent damage, repairs and maintenance work must be carried out by an after sales
service representative approved by us.
The first maintenance service should be performed by our after sales service approximately two
years after the date the appliance was first used.
The appliance must be disconnected from the power supply and the water supply isolated
before any work is carried out.
When you contact the after sales service, please quote your E no. and FD no. found on the
identification plate.
Flow at switch on
Power kW
230
8.8
220
210
7.3
Flow at switch off
Power kW
230
8.8
220
210
7.3
8
8
3.7 +/- 0.2 l/min
Temperature increase K
33.4 +/- 2.7
30.6 +/- 2.5
27.8 +/- 2.2
3.2 +/- 0.2 l/min
Temperature increase K
38.6 +/- 3.6
35.3 +/- 3.2
32.2 +/- 3.0