DE 05200
Voltage V
Formula: cold water inlet temperature + flow at switch on = hot water outlet temperature
Example: For 220 V / 4.0 kW and 2.5 l/min
15 ºC + 22.6 K = 37.6 ºC
DE 05200
Voltage V
Formula: cold water inlet temperature + temperature increase (at l/min) = hot water outlet temperature
Example: For 220 V / 4.0 kW and 1.8 l/min
15 ºC + 31.4 K = 46.4 ºC
DE 07200
Voltage V
Formula: cold water inlet temperature + flow at switch on = hot water outlet temperature
Example: For 220 V / 6.4 kW and 3.2 l/min
15 ºC + 28.1 K = 43.1 ºC
DE 07200
Voltage V
Formula: cold water inlet temperature + temperature increase (at l/min) = hot water outlet temperature
Example: For 220 V / 6.4 kW and 2.6 l/min
15 ºC + 34.6 K = 49.6 ºC
14
Flow at switch on
Power kW
230
220
210
Flow at switch off
Power kW
230
220
210
Flow at switch on
Power kW
230
220
210
Flow at switch off
Power kW
230
220
210
4.4
4
3.7
4.4
4
3.7
7
6.4
5.8
7
6,4
5,8
2.5 +/- 0.2 l/min
Temperature increase K
24.7 +/- 2.9
22.6 +/- 2.7
20.6 +/- 2.4
1.8 +/- 0.2 l/min
Temperature increase K
34.3 +/- 5.6
31.4 +/- 5.1
28.6 +/- 4.6
3.2 +/- 0.2 l/min
Temperature increase K
30.7 +/- 2.9
28.1 +/- 2.6
25.6 +/- 2.4
2.6 +/- 0.2 l/min
Temperature increase K
37.8 +/- 4.3
34.6 +/- 4.0
31.5 +/- 3.5