Transformer:
Connecting line Solenoid valve block /
Connecting line Light:
Receiver:
Antenna position
Transmitter
Coding plug:
18
English
Fittings
The external transformer provides 50 VA. The
transformer must be installed in the dry area (pro-
tected zone 3). The transformer can be installed
together with the receiver in a plastic housing, while
observing EN/IEC 60335-1 (dimensions approx.
250 x 160 x 92 mm, not included in the delivery).
The included cable allows the installation of the
transformer, up to 7 m away from the receiver. For
this, you must provide an empty pipe EN35 (not
included in the delivery). This empty pipe must be
affi xed at least every 500 mm and the bending
radius must be greater than 100 mm.
The secondary line of the transformer, which is
approx 7 m long, must not be shortened. The un-
used line length should be stored near the safety
The solenoid valve block line (7.50 m) may not
be shortened. The excess cable length should be
stored near the receiver.
The solenoid valve block line may only be routed
in the enclosed empty pipe (EN 20).
This empty pipe must be affi xed at least every 500
mm and the bending radius must be greater than
100 mm.
The receiver should be installed in the same room
as the shower system.
If this is not possible, the receiver can also be instal-
led in a room adjacent to the shower system.
The receiver must not be installed inside a metal
housing, as this would prevent it from receiving the
radio signals of the transmitter. Furthermore, you
must make sure that there are as few shielding metal
parts present in the vicinity of the receiver.
If the service mode is activated, the LED of the cod-
ing plug will display the visual return messages.
The coding plug must remain accessible.
Assembly see page 209
transformer. A damaged connecting line must not
be replaced. The transformer may no longer be
used.
A damaged connecting line must not be replaced.
0
:
No electrical lines carrying a voltage
Important
of more than 12 V may be routed in the empty
pipes for the solenoid valve block line.
The receiver antenna should be facing the transmit-
ter to optimally detect the radio signals.