1. GENERAL INFORMATION
SPECIFICATIONS
I
MODEL NO.'s
Nominal Capacity (KW)
Electrical Rating
FL Amps (ComplMotor)
This air conditioner is designed for:
A.
Installation on a recreational vehicle or caravan ve-
hicle at the time the vehicle is manufactured.
B.
Installation and use on the roof of a RV/caravan only.
C.
Connection to an air distribution system located in the
ceiling/roof cavity of the RV/caravan.
D.
Roof construction with rafters/joists on minimum of
16"/400mm centers.
E.
Minimum of 1.75"/45mm and maximum of 4.5"/1 15mm
distance between roof to ceiling of caravan required.
Alternate installation methods will allow for roofs more
tan 4.5"/115mm thickness.
F.
The air conditioner may be operated on motor genera-
tor sets which provide the proper voltage, electrical
cycles, and phase of operation when unit is in opera-
tion.
*
The Manufacturer of this air conditioner gives only
general guidelines for generator requirements. These
generator requirements come from experiences con-
sumers have with our equipment in field applications.
When sizing generators, the total electrical power
consumption of the caravan must be considered.
Keep in mind that generators lose power because of
altitude increases above sea level, high outside tem-
peratures, and lack of maintenance.
* GENERATOR REQUIREMENTS
1 Unit:
2 Units:
2.
PRECAUTIONS FOR SAFE
OPERATION
Read
A.
these Operatinq Instructions thoroughly and
carefully before attemptina operation of the air condi-
tioner.
B.
The Manufacturer will not be liable for any damages or
injury due to failure to follow these operation instruc-
tions.
C.
DO NOT add any devices or accessories to this
equipment not specifically authorized by the manufac-
turer.
CAL
CAL
136.303
61.501
61.401
3.2
2.1
2.1
220-240V, 50 Hz., Ph. 1
4.9/0.8
3.4/0.8
4.0/0.8
3.5 KW
5.0 KW
D.
This equipment must be serviced only by qualified
service personnel. Some areas require service per-
sonnel to be licensed.
CAL
OPERATING INSTRUCTIONS
3.
A.
COOLING OPERATION
1.
Place the Temperature Set Lever to desired tem-
perature level.
2.
Place the Fan Speed Switch to the position that
best satisfies your needs:
a.
b. Low Speed: Selected when RV/caravan
3. Select Auto/On Switch operation as follows:
a.
b. On Position: Air conditioner fan runs con-
4. Set the Heat/Off/Cool Switch to cool position.
The air conditioner compressor will now come on when
cooling is required and cycle off when the temperature
level selected is reached.
THERMOSTAT
HEAT\OFF\
SWITCH
Wait at least two (2) minutes before restarting the air
conditioner after shutting off with either the Heat/Off/
Cool Switch or the Temperature Set Lever. This allows
the refrigerant pressure on the air conditioner to
equalize and will allow the compressor to restart
easily.
B. HEATING OPERATION:
(If furnace is connected to the thermostat)
1.
2.
2
High Speed: Selected when maximum cool-
ing and dehumidification are required.
reaches the desired comfort level and needs
to be maintained. Normally this speed is used
for nighttime operation.
Auto Position: Airconditionerfan runs when-
ever cooling is required and stops whenever
cooling is not required.
tinuously to circulate air in the RV/caravan.
\
COOL
Set the Temperature Set Lever to desired indoor
temperature.
Set the Heat/Off/Cool Switch to heat position.
TEMPERATURE