Ermenrich Zing CT30 Auto Tester
EN
Please carefully read the safety instructions and the user manual before using this product. Keep away from children. Use the
device only as specified in the user manual.
Getting started
Open the battery compartment cover and insert a 12V 23A battery. Close the cover.
Usage
Switch the ignition of the vehicle off.
The device comes with a blade fuse. Take it out of the fuse jack (2).
Remove the vehicle's fuse from the circuit and insert it into the fuse jack (2) to provide the necessary level of circuit protection.
Insert the plug (1) into the vehicle fuse socket.
Switch the ignition on to energize the circuit, if necessary. Press (4) to turn the device on. The measured value will be shown on the
screen. Press (4) again to turn the device off.
When the low battery icon (
Specifications
Measuring range of current
Max. load
Fuse type
Max. test time
Operating temperature range
Power supply
The manufacturer reserves the right to make changes to the product range and specifications without prior notice.
Care and maintenance
Use the device only within the permitted range. Do not use the device if it is not working properly. Please note that the parameters of
the power supply must comply with the technical characteristics of the device. Do not try to disassemble the device on your own for any
reason. For repairs and cleaning of any kind, please contact your local specialized service center. Protect the device from sudden impact
and excessive mechanical force. Store the device in a dry cool place. Only use accessories and spare parts for this device that comply with
the technical specifications. Never attempt to operate a damaged device or a device with damaged electrical parts! If a part of the device or
battery is swallowed, seek medical attention immediately. Keep away from children.
Battery safety instructions
Always purchase the correct size and grade of battery most suitable for the intended use. Always replace the whole set of batteries at one
time; taking care not to mix old and new ones, or batteries of different types. Clean the battery contacts and also those of the device prior
to battery installation. Make sure the batteries are installed correctly with regard to polarity (+ and –). Remove batteries from equipment
that is not to be used for an extended period of time. Remove used batteries promptly. Never short-circuit batteries as this may lead to high
temperatures, leakage, or explosion. Never heat batteries in order to revive them. Do not disassemble batteries. Remember to switch off
devices after use. Keep batteries out of the reach of children, to avoid risk of ingestion, suffocation, or poisoning. Utilize used batteries as
prescribed by your country's laws.
Levenhuk International Lifetime Warranty
All Levenhuk telescopes, microscopes, binoculars, and other optical products, except for their accessories, carry a lifetime warranty
against defects in materials and workmanship. A lifetime warranty is a guarantee on the lifetime of the product on the market. All Levenhuk
accessories are warranted to be free of defects in materials and workmanship for six months from the purchase date. The warranty entitles
you to the free repair or replacement of the Levenhuk product in any country where a Levenhuk office is located if all the warranty conditions
are met.
For further details, please visit: www.levenhuk.com/warranty
If warranty problems arise, or if you need assistance in using your product, contact the local Levenhuk branch.
) appears on the screen, please replace the battery.
0.01–19.99 A
20A / 48V DC
standard
10 seconds
0...+40°C (operating), −10...+50°C (storage) / +32...+104°F (operating),
+14...+122°F (storage)
1pc 12V 23A battery