Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 91
28
Operation
It is used to record the work done. There are 3 memories. The led of whichever program is processed (7)
EN

7-) PROGRAM SELECTION

will burn. To save the program, it is necessary to press the button once and switch to the other program. If
you are going to record in the program number 3, it will be enough to press the button once to save your
settings after the P3 led is on. Thus, all program leds will be off. After the P3 program, there is an area that
allows the program to work without registering. While in this area, the program will not be recorded and
the program leds will be off.
• P1 - P2 - P3
Setting Range
Trigger mode selection will be made. Each time the button (8) is pressed, the other trigger mode is switched.
8-) TRIGGER MODE SELECTION
• 2 Trigger
Setting Range
• 4 Trigger
• Method
2 TRIGGER MODE : When the torch trigger is pressed, welding starts and the trigger will be held pressed
Press the Trigger
until the welding ends. Releasing the trigger will end the welding.
• Press and hold the torch trigger.
Welding Start;
• Shielding gas flow starts as long as the pre-gas period.
• At the end of the pre-gas period,
the wire feed motor runs at a slow speed.
• Welding current increases when
the workpiece is reached.
USER MANUAL
Hold the Trigger Pressed
• Release the pressed torch trigger.
Welding Termination;
• The wire feed motor will stop.
• The arc extinguishes after the set burn-back time.
• The process ends after the final gas period.
PrG : Initial Gas Time
PoG : Final Gas Time
I
: Welding Current
SMART SERIES
Release Trigger
www.magmaweld.com

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Id 500m pulse smartId 300m smartId 300m pulse smartId 300mw smartId 300mw pulse smartId 400m smart ... Alle anzeigen

Inhaltsverzeichnis