Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 8
6) Enter the Bluetooth APP control interface
If the Bluetooth connection is not successful, you can press and hold the
"Settings" and "Power On/Off" buttons at the same time for three seconds, and
wait for the Bluetooth logo on the screen to reset and flash, and then connect
again.
Error code description
When the compressor, module, fan, temperature sensing head are abnormal
and the input voltage is too low, an error code will appear on the display
screen, and the compressor will stop working. When the abnormality is elimi-
nated, unplug the power supply and plug it back in to return to the temperature
display in the box and the compressor cooling mode will start to work after 1
minute.
ENGLISH - 009
See the table below for code description
Error code
Problem description
The temperature sensor
E 0
is damaged
E 1
The input voltage is too low
DC fan overcurrent protec-
E 2
tion
Compressor start abnormal
E 3
protection
Compressor speed abnor-
E 4
mal protection
Module temperature is too
E 5
high

Technical Parameters

Model
ED40
Input voltage
DC 12V/24V, AC 100-240V
Temperature control range
-20<C~20<C(-4℉~68℉)
Refrigerant
R134a
Insulation materials
Polyurethane foam
60W±20%
Electricity power
Rated current
5.0A/2.5A
Net weight
15.5Kg
Product size(L*W*H)mm
674*409*466
Packing size(L*W*H)mm
770*520*525
ENGLISH - 010
Solution
Check or replace the tem-
perature sensor
Check the input voltage
Check the cooling fan
Power off and stand for 30
minutes to restart
Adjust compressor operat-
ing mode ( MAX/ECO)
Move the refrigerator to a
ventilated
ED50
ED60
15.9Kg
16.3Kg
674*409*516
674*409*583
770*520*575
770*520*642

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ed40Ed50Ed60

Inhaltsverzeichnis