CONTENTS

1. PRODUCT DESCRIPTION ______________ 4

2. SPECIFICATIONS ___________________ 4

3. SAFETY WARNINGS _________________ 4

4. CAUTION _______________________ 5
5. OIL PUMP USE INSTRUCTIONS __________ 5
6. NOTES REGARDING ENVIRONMENTAL _____
PROTECTION _____________________ 5
7. CONTACT _______________________ 5
WARNING!
Please read the operating instructions
carefully prior to use and observe all
safety instructions. Non-compliance
can lead to personal injury, damage to
the device or to your property. Keep the
original packaging, the purchase receipt
as well as these instructions for future
reference. When passing on this product,
pass on these instructions as well. Before
operating, check that the contents of the
package are intact and complete.
1. PRODUCT DESCRIPTION
This oil pump is designed for clean replacing of oil and/or
draining engine oil, diesel or fuel oil.
1. Pumping hose ø 6 mm
2. Oil pump
3. Outlet hose ø 12 mm
4. ON/OFF switch
5. Power cord with battery clips 12 V
4
5
1
4
3
2
2. SPECIFICATIONS
Voltage:
Current consumption:
Max. Time of use:
Volume:
Temperature range (environment): -10°C - +40°C
Max. Oil temperature:
Max. Diesel temperature:
Conveying speed:
Max. Head:
Max. Pressure:
Dimensions:
Weight:
3. SAFETY WARNINGS
• Before use make sure that the pump, the hoses and the
cable are in perfect condition.
• Damaged cables or connections should be replaced
only by authorized qualifi ed persons.
• Children must not play with the appliance. Cleaning
and user maintenance tasks must not be carried out by
children unless they are supervised.
• Do not perform any modifi cation or dismount the
device by yourself.
• Ensure that the hoses and cables can not be damaged
by sharp edges and can not get in contact with hot
surfaces.
• Do not pump gasoline, kerosene or other highly
fl ammable liquids! EXPLOSION HAZARD!
• Do not pump water or gear oil: this may cause damage
to the pump.
• When connecting the battery clips, keep correct
polarity!
• Always switch the engine off when pumping.
• Always heat engine oil up before pumping!
• Never let the pump "running idle" When oil pumping is
interrupted, switch the pump off immediately.
12 V DC
approx. 5 A
30 min
approx. 70 dB (A)
60 °C
45 °C
0.2 - 1.5 l/min
depending on liquid
and temperature
0.7 m
3 bar
approx.13 x 9 x 9 cm
approx. 975 g