Valid for: RACM40-05SK/OF; RACM40-12SK/OF; RACM40-15SK/OF;
RACM40-18SK/OF; RACM40-24SK/OF; RACM40-36SK/OF; RACM40-48SK/OF
Installation and Operating Instructions
AC/DC Power Supply: RACM40-K/OF
Other applicable document:
Important Safety Information
Technical Data
At 115/230VAC, full load forced air cooling, 25°C,
with 5 minute warm-up time unless otherwise stated
nom. Output Power – continuous
Output Voltage (Factory Setting)
Output Current
Efficiency
Nominal Input Voltage Range
Input Voltage Range
AC Input Frequency Range
Input Current
Inrush Current (cold start)
Hold Up Time
Over Voltage Protection
Output Reverse Voltage Protection
Over Current Protection
Operating Temperature
Storage Conditions
Operating Humidity
Operating Altitude
horizontal (standard)
Dimensions / Weight
AC
DC
Approvals
Warranty
Fig. 1: Mounting / Montage
vertical / vertikal
vertical
If module is horizontal or side mounted no derating is required. If module is mounted vertical or
upside down with natural convection cooling, the power must be derated at least 10%.
Wenn das Modul horizontal oder seitlich montiert wird, ist keine Leistungsrücknahme erforderlich. Wenn
das Modul, bei natürlicher Konfektionskühlung, vertikal oder kopfüber montiert wird, muss die Leistung um
mindestens 10% verringert werden.
Fig. 2: Block Diagram / Block Diagramm
upside-down
T3.5A
airflow
L
Input Filter
AC
DC
Eingangs-
Gleichrichter
N
filter
Flyback Controller
Flyback-Steuerung
Fig. 3: Derating Graph / Temperaturverhalten
RACM40-05SK/OF
40
35
30
25
20
15
12
10
9
115-240VAC nom.
5
100VAC nom.
0
-40
-30
-20
-10
0
10
20
30
40
Ambient Temperature [°C]
Umgebungstemperatur [°C]
Technische Daten
Bei 115/230VAC, Volllast, Zwangsbelüftung, 25°C, nach
5 Minuten Aufwärmzeit, wenn nicht anders angegeben
nom. Ausgangsleistung - dauerhaft
Ausgangsspannung (Werkseinstellung)
Ausgangsstrom
Wirkungsgrad
Nominaler Eingangsspannungsbereich
Eingangsspannungsbereich
Eingangsfrequenz
Eingangsstrom
Einschaltspitzenstrom (Kaltstart)
Pufferzeit
Überspannungsschutz
horizontal (standard)
Überspannungsschutz (Rückkopplung)
AC
DC
Überstromschutz
Betriebstemperatur
airflow
Lagerbedingungen
Betriebsluftfeuchtigkeit
Betriebshöhe
vertical
Abmessungen / Gewicht
Zulassungen
Garantie
horizontal (standard)
AC
DC
Luftstrom
airflow
vertical
upside-down
upside down / kopfüber
AC
DC
Active
Output Filter
Rectifier
Rectification
Ausgangs-
Aktive
filter
Gleichrichtung
upside-down
Snubber
Feedback
Regelstrecke
Snubber
Rectification Controller
AC
DC
+ Feedback Loop
Steuerung für die aktive Gleichrichtung +
Regelung der Ausgangsspannung
all other models
alle anderen Modelle
40
35
30
25
20
16
15
10
115-240VAC nom.
5
100VAC nom.
0
50
60
70
80 90
-40
-30
-20
-10
0
55
85
Ambient Temperature [°C]
Umgebungstemperatur [°C]
Revision: 0/2020
Document no.: IMG132
©RECOM Power GmbH. The information contained in
this instructions and accompanying drawings are the
intellectual property of RECOM Power GmbH.
This manual can change without prior notice.
RACM40-05SK
RACM40-12SK
RACM40-15SK
/OF
/OF
30W
40W
5VDC
12VDC
6000mA
3334mA
87%
90%
105% - 120%, hiccup mode / 105% - 120%, automatischer Neustart
107% - 145%, hiccup mode / 107% - 145%, automatischer Neustart
130% - 180%, Hiccup Mode / 107% - 145%, automatischer Neustart
-40°C to +85°C with derating at natural convection (0.1m/s) (refer to Fig. 2) / mit Leistungsreduzierung bei natürliche Konvektion (siehe Fig. 2)
-40°C to +90°C, 95% RH max. (non condensing) / (-40°C bis +90°C, 95% RH max. (nicht kondensierend)
4000m (according to 60601-1), 5000m (according to 62368-1) / 4000m (nach 60601-1), 5000m (nach 62368-1)
IEC/EN62368-1, IEC/EN60335-1, ANSI/AAMI ES60601-1, CAN/SA-C22.2 No. 60601-1, IEC/EN61010-1, EN62233, IEC/EN61558-1, IEC/EN61558-2-16
Fig. 4: Mechanical Dimension / Maßzeichnung
Dimension Drawing (mm) / Maßzeichnung (mm)
airflow
Luftstrom
CON1
+V
-V
airflow
#
1
3
4,5
6,7
FC = fixing centers
Compatible Connector
10
20
30
40
50
60
70
80
90
55
85
Molex 41695 Series
Crimp Terminal
*
TechsupportAT@recom-power.com
RACM40-18SK
RACM60-24SK
/OF
/OF
/OF
40W
40W
40W
15VDC
18VDC
24VDC
2667mA
2222mA
1667mA
90%
90%
90%
100-240VAC
80-264VAC or 120-370VDC
47Hz – 63Hz
1000mA @115VAC / 500mA @230VAC
15A @115VAC / 30A @ 230VAC
16ms @115VAC / 60ms @230VAC
95% RH max.
78.3 x 40.6 x 25.1mm / 74g typ.
3 years / 3 Jahre
6.10
Top View
1
Draufsicht
3
6x 1.14
80.2
68.9
Front View
Ansicht von Vorne
78.3
FC 36.0
FC 36.0
31.39
Ø2.0
IC101
Bottom View
Ansicht von unten
Ø5.0
Ø4.0
38.36
18.63
Connector Information
Function
Terminal
AC Input (CON1)
VAC in (N)
3 Pins (Pin2 removed)
VAC in (L)
with 3.96mm pitch
DC Output (CON2)
-VDC out
4 Pins
+VDC out
with 3.96mm pitch
Housing
Molex 2478
RECOM Power GmbH
Münzfeld 35, 4810 Gmunden, AUSTRIA
+43 7612 88325 700
+43 7612 88325 801
7
www.recom-power.com
RACM40-36SK
RACM40-48SK
/OF
/OF
40W
40W
36VDC
48VDC
1111mA
833mA
90%
90%
3.30
General tolerances according to ISO 2768-m
(table for reference only)
Allgemeintoleranzen gemäß ISO 2768-m
(Tabelle nur als Referenz)
7
Dimension range
Tolerances
6
Nennmaßbereich
Toleranzen
5
0.5 - 6 mm
±0.1 mm
4
6 - 30 mm
±0.2 mm
30 - 120 mm
±0.3 mm
120 - 400 mm
±0.5 mm
DC Output Side View
DC Ausgangsseite
CON2
AC Input Side View
AC Eingangsseite
4x Ø2.60
CON1
Anschluss
#
Funktion
Stiftleiste
AC Eingang (CON1)
1
VAC in (N)
3 Pins (Pin2 ausgelassen)
3
VAC in (L)
mit 3.96mm Abstand
DC Ausgang (CON2)
4,5
-VDC out
4 Pins
6,7
+VDC out
mit 3.96mm Abstand
FC = Montagelöcher
Kompatibler Stecker
Gehäuse
Molex 41695 Serie
Kabelgehäuse
Molex 2478