IMPORTANT NOTE
• Read and keep these instructions.
• Do not cover the ventilation holes with any
items such as newspapers, curtains etc.
• Do not clean the unit with abrasive or
corrosive materials.
• Do not tamper with the unit's internal
components. This invalidates the warranty.
• Only use fresh batteries. Do not mix new and
old batteries.
• Do not dispose old batteries as unsorted
municipal waste. Collection of such waste
separately for special treatment is necessary.
• Attention! Please dispose of used unit or
batteries in an ecologically safe manner.
• Technical specifications and user manual
contents for this product are subject to
change without notice.
1
CAUTION
• Danger of explosion if battery is incorrectly
replaced. Replace only with the same or
2
equivalent type.
• Battery cannot be subjected to high or low ex-
treme temperatures, low air pressure at high
altitude duning use, storage or transportation.
• Replacement of a battery with an in correct
type that can result in an explosion or the
leakage of flammable liquid or gas.
• Disposal of a battery into fire or a hot oven, or
mechanically crushing or cutting of a battery,
that can result in an explosion.
• Leaving a battery in an extremely high temper-
ature surrounding environment that can result
in an explosion or the leakage of flammable
liquid or gas.
• A battery subjected to extremely low air
pressure that may result in an explosion or
the leakage of flammable liquid or gas.
• An appliance is only suitable for mounting at
height ≤ 2m
EC DECLARATION OF CONFORMITY
Hereby, Bresser GmbH declares that
the equipment type with part number:
7009975 is in compliance with
Directive: 2014/53/EU. The full text of the EU
declaration of conformity is available at the
following internet address:
www.bresser.de/download/7009975/CE/7009975_CE.pdf
UKCA DECLARATION OF CONFORMITY
Bresser UK Ltd. has issued a
„Declaration of Conformity" in
accordance with applicable guidelines
and corresponding standards. The full text of
the UKCA declaration of conformity is available
at the following internet address:
www.bresser.de/download/7709975/UKCA/7009975_UKCA.pdf
Bresser UK Ltd. • Suite 3G, Eden House, Enterprise
Way, Edenbridge, Kent TN8 6HF, Great Britain
NOTES ON CLEANING
• Remove the batteries before cleaning.
• Only use a dry cloth to clean the exterior of the
device. To avoid damaging the electronics, do not
use any cleaning fluid.
• Protect the device from dust and moisture.
WARRANTY & SERVICE
The regular guarantee period is 5 years and
begins on the day of purchase. You can consult
the full guarantee terms and details of our servic-
es at www.bresser.de/warranty_terms. Would
you like detailed instructions for this product in
a particular language? Then visit our website via
the link below (QR code) for available versions.
www.bresser.de/warranty_terms
OVERVIEW
1
2
5
6
7
8
3
4
1.
Buzzer
2.
LED indicator
3.
Sensor contact wall mounting holder
4.
Water sensor
5.
Wall mounting holder
6.
[CHANNEL], slide switch
7.
[RESET] key
8.
Battery compartment
GETTING STARTED
1. Remove the battery door.
2. Slide the [CHANNEL] slide switch to assign
the sensor to a channel from channel
1,2,3,4,5,6 or 7.
3. Insert 2 x AA size batteries into the battery
compartment according to the polarity mark
on the battery compartment..
4. Close the battery door.
5. After inserting batteries, the transmission
status LED will light up 1 sec
NOTE:
- Ensure to assign different channels of different
sensors, in case you need to pair more than
one sensors.
- Once the channel is assigned to a wireless
waster leaksensor, you can only change it by
removing the batteries or resetting the unit.
- Avoid placing the sensor in direct sunlight, rain
or snow
PAIRING THE WIRELESS SENSORS
WITH THE CONSOLE
The console will automatically search and
connect to your wireless sensor(s). Once your
sensor(s) pair up successful, the sensor(s)
signal strength indication and weather
information will appear on your console display.
NOTE:
During signal transmission, the LED indicator of
the sensor will flash.
WHEN DETECTED THE WATER LEAK
Once the water leak sensor detected a water
leak, the sensor emits a 90dB alarm and trans-
mits data to the console once every 1 minute.
After you address the cause of the alert and wipe
dry the water sensor, the water sensor will detect
"dry" in its placed area, the water leak sensor will
auto stop the alarm sound after then.
NOTE:
You can mute the water leak sensor by removing
the batteries from the battery compartment.
5
HOW TO PLACE THE SENSOR
- Choose a location where water leaks are likely
to occur. For the most part, this sensor will be
6
7
placed near water sources, or anywhere you
think leaks are possible.
- Choose a location that shields the sensor
from direct sunlight for an accurate reading.
8
- Minimize obstructions such as doors, walls,
furniture, etc. And make sure the transmission
is within 150 meters approx.
3
- The main sensor unit must hang with the wall
mount hole, but the detection unit can hand it
4
with wall mount hole or place it directly on flat
surface, and make sure the transmission is
within 150 meters approx.
RESET THE SENSOR
In case of mal-function, press the [RESET] button
to reset the sensor.
SPECIFICATIONS
Dimensions (WxHxD)
125 x 58 x 19 mm
Weight
144g (with batteries)
2 x AA size 1.5V batteries
(Lithium battery recom-
Main power
mended for low tempera-
ture environment)
Weather data
Water leak
RF frequency
868MHz
150m (490 feet) straight
RF transmission range
distance
HANG THE MAIN SENSOR WITH THE WALL MOUNT HOLE
LAY THE DETECTION UNIT ON THE GROUND OR MOUNT IT ON A WALL
Sensor detecting
3 seconds after the water
interval
leak detected
Sensor reporting
60 seconds after the water
interval
leak detected
Number of channels
7 (CH1 ~ 7)
RF normal Transmis-
60 seconds
sion interval
Operating temperature
-20 ~ 60°C (-4 ~ 140°F)
range
Operating humidity
RH 1% to 99 %
range
DISPOSAL
Dispose of the packaging materials
properly, according to their type, such as
paper or cardboard. Contact your local waste-dis-
posal service or environmental authority for
information on the proper disposal.
Do not dispose of electronic devices in the
household garbage! As per the Directive
2002/96/EC of the European Parliament
on waste electrical and electronic equipment and
its adaptation into German law, used electronic
devices must be collected separately and
recycled in an environmentally friendly manner.
In accordance with the regulations
concerning batteries and rechargeable
batteries, disposing of them in the normal
household waste is explicitly forbidden. Please
make sure to dispose of your used batteries as
required by law — at a local collection point or in the
retail market. Disposal in domestic waste violates
the Battery Directive. Batteries that contain toxins
are marked with a sign and a chemical symbol.
1
battery contains cadmium
battery contains mercury
2
battery contains lead
3
Cd¹
Hg²
Pb³
Bresser GmbH
Gutenbergstr. 2, DE-46414 Rhede, Germany
Bresser UK Ltd.
Suite 3G, Eden House, Enterprise Way, Edenbridge,
Kent TN8 6HF, Great Britain
Service:
Web: www.bresser.de/weather
E-Mail: service@bresser.de
Besuchen Sie uns auf • Find us on:
Manual_7009975_Watersensor_de-en_BRESSER_v122021a
loading

Inhaltszusammenfassung für Bresser 7009975

  • Seite 2 Höhe ≤ 2m geeignet. 3. Entfernen Sie das Batteriefach und legen Sie 2 x AA-Batterien in das Batteriefach ein, EG-KONFORMITÄTSERKLÄRUNG entsprechend der Polaritätsmarkierung auf Hiermit erklärt die Bresser GmbH, dass dem Batteriefach. der Funkanlagentyp mit 4. Batteriefachabdeckung schließen. Artikelnummer: 7009975 der Richtlinie: 5.