Operation manual SANlight Q1W DIM
By purchasing a SANlight Q1W DIM LED-light you have decided on a high-quality product, which will give you much pleasure.
Please read the operating instructions before using your Q1W DIM LED-light, as incorrect use can cause damage to the lamp or
plants. If the Q1W is not used properly, all warranty claims and the manufacturer's product liability expire.
ATTENTION photobiological safety advice: The Q1W DIM LED module is used exclusively for illuminating plants and is not intended for general lighting purposes. According to DIN EN 62471, the Q1W DIM LED module is classified in risk
group 1. Nevertheless, avoid unnecessarily long irradiation and looking directly into the light source.
Guarantee Policy
This device has been designed, manufactured and tested in
accordance with the European safety standard (EN60598/CE). The
guarantee for the LED-light and accessories is 3 years from the
date of purchase. The guarantee does not apply to equipment that
has not been installed and maintained as specified in this manual.
The manufacturer assumes no responsibility for damage caused
by unauthorized or incorrect use. In case of damage, the device
(LED-light incl. power supply) must be returned to the respective
SANlight sales partner, from whom the product was purchased.
They send the defective goods to the manufacturer, SANlight
GmbH. After repair by the manufacturer, the device is returned to
the respective sales partner.
Work and repairs
Repairs and works may only be carried out by the manufacturer.
If repairs, modifications and other works are not performed by the
manufacturer, the manufacturer 's warranty and product liability
expire.
Scope of delivery
Figure 1 shows all components of your SANlight Q1W DIM. Please
check the content of the packaging for completeness and damage.
Never use damaged components.
Fastening and suspension of the LED module
The LED module (1) can be positioned in 3 different orientations
using the two holding brackets (2). When hanging the LED-module,
keep a safety distance of 15 cm from surrounding objects. Make
sure that the brackets (2) are properly mounted and secure the
LED-module (1) sufficiently to prevent it from falling accidentally.
Installation and removal of the mounting bracket
The supplied mounting brackets (2) can be attached to the two
grooves in the edge area of the heat sink and thus allow the lamp
to be oriented flexibly. Figures 2 and 3 show the different mounting
options. To hang in the retaining bracket (2), spread it apart by
hand. Figure 4 illustrates the installation and removal of the retaining
bracket (2).
Electrical connection of the Q1W DIM
For powering, the LED-module (1) must be connected to the
power-supply unit (4). To do this, connect the plug of the DC
supply-cable (3) on the LED-module to the socket on the DC
supply-cable (5) of the power-supply unit (4). For this purpose, the
plug and the socket have printed arrows that must point towards
each other. (see Fig. 5)
Connection sequence
The attachment order as shown in Figures 5 and 6 must be
observed. First connect the DC supply-cable (3 and 5) then the AC
supply-cable (6). When disconnecting the Q1W DIM from the mains
power supply proceed in the reverse order (first unplug the AC
supply-cable, then the DC supply-cable). Disregarding this advice
can cause damage to the Q1W DIM and will void all warranty and
product liability claims.
Laying the cables
When laying all cables, ensure a strain-relieved fixation. Cabling
should not be exposed to tensile load. All cables must be comple-
tely unwound. The LED-module (1) and the power-supply unit (4)
must not be operated with coiled cables.
Power supply
When using several Q1W DIM modules, a distance of at least 10mm
must be maintained between the individual power supplies. Sta-
cking the power-supply units (4) is not permitted.
ATTENTION: The AC power-plug is not waterproof. Avoid direct
contact with liquids of all kinds and only operate the power-supply
unit in rooms with a humidity below 80%.
Dimming function
You can control the dimming function with the rotary switch on the
driver. The dimming power ranges from 0% - 100% and is
subdivided in 20% steps: 0% - 20% - 40% - 60% - 80% - 100%.
(Figure 4)
Attention: Do not look
directly into the light source.
Ne regardez pas directement
dans la source lumineuse.
Attention: The light is not
suitable for covering!
La
lumière n'est pas adaptée
pour couvrir!
3
5
1. LED Module
6
2. Mounting Brackets
1
3. DC Power Cord with Plug
2
4. Power Supply, Main Power Cord
5. DC Power Cord with socket
6. Power plug, AC Power Cord
4
Figure 1
Contact manufacturer: SANlight GmbH, Montafoner Str. 14, 6780 Schruns, Austria, www.sanlight.com, support@sanlight.com
Good luck using your SANlight lamp. For questions, suggestions or further information, please contact your dealer or us.
Handling the LED module and general warnings
To clean the secondary optics of your Q1W DIM, please use a soft, non-abrasive cloth with distilled water. Under no circumstances should you use other
aids such as cleaning agents, damp cloths, etc. For cleaning, the luminaire must be disconnected from the mains. Make sure that the secondary optics
are not scratched by cleaning. Scratched or damaged secondary optics result in reduced light output and poor light control. To clean the heat sink,
please also use a soft, non-abrasive cloth with distilled water. For very heavy soiling, you can use a mild soapy water solution.
Hazard warnings
ATTENTION: Avoid direct contact of the LED module (1) with plant parts.
ATTENTION: The Q1W DIM may be operated up to a maximum ambient temperature of 35 °C. The minimum ambient temperature at which the Q1W
DIM may be operated, is 5 °C.
ATTENTION: Avoid unnecessary mechanical stress on the LED-module, the power-supply, and all cables.
ATTENTION: Carefully secure the LED-module (1) against falling and mechanical stress of any kind.
ATTENTION: The LED-module (1) can become up to 65 °C hot depending on the ambient temperature. Make sure there is sufficient ventilation at the
place of use and keep a safety distance of at least 15 cm from surrounding objects. The LED-module (1) must not be operated in closed rooms without
air supply.
ATTENTION: Use the Q1W DIM only with the included power-supply. (4) The use of other power-supplies will destroy the LED-module.
ATTENTION: If damage can be seen on the power-supply unit, on the LED-module, on the cables or on the suspension, the Q1W DIM must no longer
be operated. In this case, disconnect the Q1W from the general power-supply immediately. To do this, pull the mains connection cable out of the socket.
Technical data
LED-module power consumption typ.
Power-supply supply voltage
Power-supply Input voltage frequency
Power-supply Power factor
LED-module operating voltage
LED-module operating current
Power-supply maximum output voltage
Maximum ambient temperature for operation
Minimum ambient temperature for operation
Maximum humidity for operation
LED-module maximum temperature
Power-supply maximum temperature
Emission range
Dimensions of LED-module
Dimensions of power-supply
Weight of LED-module including connection cable
Weight of power-supply unit including connection cable
Module efficiency in range of emission wavelengths
BPF
Degree of protection power-supply
Degree of protection LED-module
Protection class power-supply
Dimming function
The LED-light must not be disposed of in household waste! For disposal, the light can be handed back to the manufacturer. The disposal costs are borne by the manufacturer. Alternatively, the light can be delivered to a
disposal company for electrical appliances.
La lampe LED ne doit pas être jetée avec les ordures ménagères! Pour l'élimination, la lumière peut être restituée au fabricant. Les coûts d'élimination sont à la charge du fabricant.
Alternativement, la lumière peut
être livrée à une entreprise d'élimination des appareils électriques.
Caution: Risk of shock. Disconnect power before
relamping.
Attention: Risque d'électrocution. Débrancher
l'alimentation avant de remplacer la lampe.
Figure 2
Protected against solid objects with a diameter
≥ 1.0 mm; no protection against water.
Protégé
IP40
contre les corps étrangers solides d'un diamètre ≥
1,0 mm; pas de protection contre l'eau.
Figure 3
Figure 4
Read before operating
50 W
120 – 277 V (AC)
50/60 Hz
0,95
<57 V (DC)
0,8 A (DC)
90 V (DC)
35 °C
5 °C
90 %
65 °C
90 °C
410 – 760 nm
174x80x55 mm
119x68x34 mm
633 g
705,4 g
>2,7 µMol / (W*s)
125 µmol/s
IP67
IP40
I (with protective conductor)
Dim OFF, 20%, 40%, 60%, 80%, 100%
Keep a safety distance of at least 15 cm to surrounding objects.
Maintenez une distance de sécurité d'au moins 15 cm par rapport
aux objets environnants.
Figure 5