SunPower Maxeon 6 AC Residen al Solar Panel
(SPR-MAX6-XXX-BLK-E3-AC, SPR-MAX6-XXX-E3-AC, SPR-MAX6-XXX-BLK-E4-AC, SPR-MAX6-XXX-E4-AC)
0
TOP CLAMPS
Moun ng
Moun ng Configura on Diagram
Configura on
Descrip on
Front View
Back View
Long Side Moun ng,
Rails Perpendincular
to Moun ng Frame
Long Side Moun ng,
Point Supported
Long Side Moun ng,
Rails Parallel to
Moun ng Frame
Short Side Moun ng,
Rails Perpendicular
to Moun ng Frame
(End Mount)
Short Side Moun ng,
Point Supported
(End Mount)
Short Side Moun ng,
Rails Parallel to
Moun ng Frame
(End Mount)
1 Design Load considers 1.5 Factor of Safety, Test load = Design load x 1.5. Product Warranty covers only design
load values. The design loads listed in this table supersede all other loads that may be defined by other
par es, unless there is a formal authoriza on by Maxeon.
2
Test loads are for informa on purposes only, design loads should be considered for the project design.
3 Rails must not be under the Microinverter.
©2023 Maxeon Solar Technologies, Ltd. All rights reserved. Specifications included in this document are subject to change without notice.
153
525
271
373 mm
Microinverter
Exclusion Zone
249 mm
Measurement Tolerances are +/-3mm for the Length and Width of the module.
A - Ground Holes (4X Ø 4.2mm)
B - Moun ng Holes (4X Ø 6.8mm )
Moun ng Zone
Test Load
Design Load
Loca ons
Downward/Upward
Downward/Upward
(distance from corner
(Pa)
in mm)
271 - 525
+3600/-2700
+5400/-4050
+2400/-2550
+1600/-1700
525 - 729
0 - 153
+2400/-2400
+1600/-1600
153 - 271
+1600/-1600
+2400/-2400
+5400/-3600
271 - 525
+3600/-2400
525- 729
+2400/-2400
+1600/-1600
0 - 153
+1600/-1600
+2400/-2400
153 - 271
+1600/-1600
+2400/-2400
271 - 525
+5400/-3600
+3600/-2400
525- 729
+2400/-2400
+1600/-1600
0 - 356
+3600/-2400
+2400/-1600
+2400/-2400
+1600/-1600
0 - 356
0 - 356
+2400/-2400
+1600/-1600
729
729
525
1100 mm
1872 mm
(Pa)
SIDE FRAME PROFILE
40 mm
BOLTS
Moun ng
Moun ng Configura on Diagram
Configura on
Descrip on
Front View
Long Side Moun ng,
Rails Perpendincular
to Moun ng Frame
Long Side Moun ng,
Point Supported
4 In the cases where hybrid moun ng is necessary (combina on of long and short side moun ng), the lowest
design load values should be considered as allowable design load.
5 Bo om flange moun ng
6 Range indicates posi oning of the clamp and not the rails
MAXEON SOLAR TECHNOLOGIES, LTD.
0
271
153
A
B
GEN 5.2 FRAME PROFILE
END FRAME PROFILE
40 mm
32 mm
Moun ng Zone
Test Load
Loca ons
(distance from corner
Downward/Upward
Back View
in mm)
1100mm Holes
+9000/-6000
1100mm Holes
+5400/-5400
537620 Rev.G
24 mm
Design Load
Downward/Upward
(Pa)
(Pa)
+6000/-4000
+3600/-3600