- Third press: Power off the device. (FIG.6)
7. If there is no water in the water tank (C), the diffuser will be turned off automatically.
8. The product cannot be used if there is no water in the tank (C).
NOTE: The mist concentration may vary slightly, which is normal. Different types of water, humidity, temperature and air velocity affect
spray intensity.
9. Before replacing with another oil, please clean the device according to the maintenance instructions.
10. Never leave water in the tank (C) when the device is not in use.
10. After working for a long time, turn off the device for 60 minutes to avoid damaging the ultrasonic wave chip, and then restart it.
ACCIDENTAL LEAK
If you accidentally tip your device over while in use, follow these steps:
1. Turn off the power. Unplug the appliance and open the lid (B) to pour out all the remaining water from the water tank (C).
2. Gently shake the device to drain the internal water.
3. Air dry the device in a safe place for 24 hours.
DESCALING
If there is limescale build up in the aroma diffuser caused by water, you can add white vinegar to the water to dissolve the limescale,
then rinse with water. Then use a soft cloth to wipe off the water. Never use strong cleaning agents.
TROUBLESHOOTING
If this product is not working normally, please follow these steps for self- troubleshooting before sending the return to the seller:
PROBLEM 1: The product automatically turns off one second after being turned on.
POSSIBLE CAUSE: Inadequate amount of water.
SOLUTION: Please add water to the water tank.
POSSIBLE CAUSE: The power adapter is not connected to the device.
SOLUTION: Make sure the power adapter is connected to the product. To check if the connection was successful, please remove the
cable from the micro-USB socket and reconnect it
PROBLEM 2: No spray or abnormal spray
POSSIBLE CAUSE: Inadequate amount of water.
SOLUTION: Please add water to the water tank if there is not enough. If the water level inside the water tank is higher than the
maximum water level mark, the mist will be sprayed irregularly, abnormally. Drain the water so that it is below the "MAX" level.
POSSIBLE CAUSE: Ultrasonic spray chip (I) is dirty.
SOLUTION: Please clean the water tank (C) and chip (I). Oils sometimes accumulate on the ultrasonic spray chip board.
POSSIBLE CAUSE: Lower air inlet holes (H) are dusty.
SOLUTION: If the air inlet holes (G) are dusty, the volume of air drawn in will be reduced significantly and the air momentum will not be
enough to spray the mist. Clean the air intake.
PROBLEM 3: Leakage
POSSIBLE CAUSE: Lid (B) is not closed properly.
SOLUTION: Close the lid securely.
POSSIBLE CAUSE: Room temperature is too low or humidity is too high.
SOLUTION: If the temperature or humidity of the working environment is too low or too high, mist and water drops will accumulate on the
6