4.5 Checking connections

; Ensure isolation from supply (all phases).
; Make sure a restart is impossible
; Check the cables for proper fit.

4.6 Switching on the device

The device may only be switched on if it has been installed properly and
in accordance with its intended use, including the required safety
mechanisms and professional electrical hookup. This also applies for
devices which have already been equipped with plugs and terminals or
similar connectors by the customer.
WARNING
Hot motor housing
Risk of fire
→ Ensure that no combustible or flammable materials are
located close to the fan.
; Before switching on, check the device for visible external damage
and make sure the protective devices are functional.
; Check the fan's air flow paths for foreign matter and remove any
foreign matter found.
; Apply the nominal supply voltage.

4.7 Switching off the device

; Disconnect the device from the power supply at the supply line's
main switch.
; When disconnecting, be sure to disconnect the ground connection last.
Item no. 11009-5-9970 · ENU · Change 261768 · Approved 2022-06-23 · Page 8 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Operating instructions
5. MAINTENANCE, MALFUNCTIONS, POSSIBLE
CAUSES AND REMEDIES
Do not perform any repairs on your device. Send the device to ebm-
papst for repair or replacement.
Malfunction/fault
Rotor not running
smoothly
Motor not turning
Motor
overtemperature
WARNING
Live terminals and connections even with device
switched off
Electric shock
→ Wait five minutes after disconnecting the voltage at all poles
before opening the device.
CAUTION
The motor restarts automatically when operating voltage
is applied, e.g. after a power failure.
Risk of injury
→ Keep out of the motor's danger zone.
→ When working on the motor, switch off the line voltage
and ensure that it cannot be switched back on.
→ Wait until the motor comes to a stop.
If the device is out of use for some time, e.g. when in storage,
we recommend switching it on for at least two hours to allow
any condensation to evaporate and to move the bearings.
Possible cause
Imbalance in rotating
parts
Mechanical blockage
Line voltage faulty
Faulty connection
Thermal overload
protector activated
Impermissible point of
operation
Ambient temperature
too high
Deficient cooling
In the event of further malfunctions, contact ebm-papst.
Possible remedy
Clean the device;
replace it if imbalance
persists after cleaning
Switch off, isolate
from supply and
remove mechanical
blockage.
Check line voltage,
restore power supply.
Isolate from supply,
correct connection;
see connection
diagram.
Allow motor to cool
off, locate and rectify
cause of error,
release restart lockout
if necessary
Check point of
operation
Reduce ambient
temperature if possible
Improve cooling