Function and features
The encoder transforms rotational movement into pulse sequences.
These allow the measurement of linear distances and angular move-
ment as well as the determination of positions.
Electrical connection
Disconnect power from the installation before connecting or dis-
connecting cables or connectors!
Unused wires must be insulated to avoid short circuits and cross
faults.
Short-circuit protection
5V TTL version:
10...30V HTL version:
Standard wiring:
L+
L+ sensor
0V
0V sensor
A
A neg.
B
B neg.
0 index
0 index neg.
fault neg.
free
free
screen
6
outputs short-circuit protected against 0V
outputs short-circuit protected against 0V
and L+ for maximum 1 minute
Flange plug
12-pole
M
B
K
L
E
F
H
A
C
D
G
-
-
housing
13-wire cable
brown/green
blue
white/green
white
brown
green
grey
pink
red
black
lilac
-
yellow
housing