1. Reduce the pressure in the tank till approximately
2 bar by connecting and activating an air tool.
2. Then slowly turn the drain cock (11) on the lo-
wer side of the tank open. The water in the tank
will now leak out of the tank.
3. Take care when compressed air is in the tank
because the water can come out with some
force. Recommended pressure max. 1-2 Bar.
Clean the air filter (Fig. G)
It is recommended to disassemble the
suction filter every 50 operating hours and
to clean the filter element by blowing it with
compressed air.
It is recommended that the filter element is
replaced at least once a year if the
compressor is working in a clean environ-
ment; more often if the environment in
which the compressor is situated is dusty.
A clogged intake filter will decrease the
compressor's performance dramatically.
1. Open the halves of the air filter housing. Use
compressed air at low pressure (approx. 3 bar)
to blow out all the parts of the filter
2. Assemble the filter in reverse order.
STORAGE AND FROST POTECTION
The compressor and accessories that are not
completely drained can be destroyed by frost. Com-
pletely drain the compressor and accessories and
protect them against frost. Keep this appliance in
well-ventilated dry premises with temperature not
going below +5°C.
When not in use, keep this appliance stored in a
safe place out of reach of children.
Malfunction
Should the machine fail to function correctly, a
number of possible causes and the appropriate
solutions are given below:
Air loss
• May be caused by a poor seal of a connection.
• Check all air connections by wetting them with
a soapy water solution (Never use the solution
nearby electric connections).
• When the tank is empty and being filled. The
user might hear a sisseling sound by the pres-
sure switch. This is normal and will stop before
10
the compressor reach a pressure of 1.5 bar.
• Check if the drain cock (11) is closed well.
The compressor will not start
If the compressor is difficult to start, check:
• Whether the voltage of the mains corresponds
to that on the specification plate.
• Whether electrical extension cables are being
used with a faulty core or length.
• Whether the operating environment is too cold
(below 5°C).
• Whether there is electricity supply (plug properly
connected, magneto-thermal fuses not broken).
The compressor does not shut off
If the compressor does not shut off when the
maximum pressure has been reached, the safety
valve of the tank will be activated. It is necessary to
contact the nearest authorised Support Service for
the repair.
ENVIRONMENT
Faulty and/or discarded electrical or
electronic apparatus have to be collected at
the appropriate recycling locations.
Only for EU countries
Do not dispose of power tools into domestic waste.
According to the European Guideline 2012/19/EU
for Waste Electrical and Electronic Equipment and its
implementation into national right, power tools that
are no longer usable must be collected separately
and disposed of in an environmentally friendly way.
WARRANTY
VONROC products are developed to the highest
quality standards and are guaranteed free of
defects in both materials and workmanship for the
period lawfully stipulated starting from the date of
original purchase. Should the product develop any
failure during this period due to defective material
and/or workmanship then contact VONROC directly.
The following circumstances are excluded from this
guarantee:
• Repairs and or alterations have been made
or attempted to the machine by unauthorized
service centers;
• Normal wear and tear;