Max. Loop supply cable: 250 m
Max. Internal loop resistance:
20 Ω incl. supply line
Loop inputs: galvanic isolation 2 kV (via
spark gap)e)
Cycle time: 24 ms
Cable size
Connection
flexible with wire
rigid
end ferrule
X31
310-319
0,2 - 2,5 mm²
0,25 - 1,5 mm²
X32
320-325
X33
330-335
X34
340-342
0,2 - 2,5 mm²
0,25 -1,5 mm²
X36
360-363
X35
350-353
X38
380-385
0,2 - 1,5 mm²
0,25 - 0,75 mm²
X39
390-393
EC installation declaration
Machinery Directive: 2006/42/EC
Low Voltage Directive: 2014/30/EU
Harmonised standards applied:
EN 60335-1:2012 / AC:2014
Section: Chapters 7, 10, 11, 13, 14, 16, 17, 19, 22, 23, 24, 29 and 30
EN 60335-2-103:2015
Section: Chapters 7, 10, 11, 13, 14, 16, 17, 19, 22, 23, 24, 29 and 30
EN 61000-6-1:2007 Section: Table 1 item 1.5, Table 2, Table 4 items 4.4 + 4.5
EN 61000-6-2:2005 / AC:2005
Section: Table 1 item 1.5, Table 2, Table 4 items 4.4 + 4.5
4.5
UL-Ratings
Supply
24 VDC / max. 1 A, Class 2 (X30a)
Class 2 output
24 VDC / max. 700 mA
Maximum surrounding
65 °C
air temperature
Degree of pollution
For use in an environment with pollution degree 2.
Battery
Use UL Recognized lithium coin cell BR2032 by
Panasonic or Spectrum Brands Inc. only.
X38
CAN interface (PIN 381, 382):
24 VDC / max. 20 mA, Class 2
Output (Pin 380):
24 VDC / max. 0.7 A
Controller
X39
X33
Tightening
torque
X34
0,35 - 0,4 Nm
X36
0,35 - 0,4 Nm
X37 / X37a
0,22 - 0,25 Nm
X30a
X40
X300
X400 / X400a
X700
1
Note: The maximum load of all Class 2 outputs shall not exceed 0.7 A in any
combination.
X35
X31 Relays Outputs
(OUT 5,
OUT 6,
OUT 7,
OUT 8)
X32 Relays Outputs
(OUT 9,
OUT 10)
1
, Class 2
2
The relay terminals X31 and X32 can be connected either to the mains
voltage, low voltage or class 2 circuits. Mixing different voltage circuits within
one terminal is not permitted.
TST RFUxK2-A
TST_RFUxK2-A_Install_rev4_mul
RS-485 interface (PIN 391, 392):
24 VDC / max. 20 mA, Class 2
Output (Pin 390):
1
24 VDC / max. 0.7 A
, Class 2
Input 21, 22; 24 VDC each / max. 20 mA, Class 2
Digital Output; 24 VDC (Pin 333) / max. 200 mA,
Class 2
1
Output (Pin 330); 24 VDC / max. 0.7 A
, Class 2
Input 23; 24 VDC / max. 20 mA, Class 2
1
Output (Pin 340); 24 VDC / max. 0.7 A
, Class 2
Input 24, 25, 26; 24 VDC each / max. 20 mA,
Class 2
1
Output (Pin 360); 24 VDC / max. 0.7 A
, Class 2
Foil key pad connection
1
Power Supply Input; 24 VDC / max. 1 A
CAN-Bus (internal connection to the controller,
non-isolated)
Programming interface, internal (for reference
only)
Connector for display; 5 VDC, 200 mA
Anybus interface; 24 VDC / typ. 100 mA, Class 2
(for reference only)
2 inputs for external induction loop (loop detector)
2
Maximum load for each single output:
250 VAC, max. 3 A G.P.
30 VDC, 3 A G.P.
C300, R150 (Pilot Duty)
Maximum total load at all four outputs:
250 VAC, max. 3 A G.P.
30 VDC, 3 A G.P.
120 / 240 VAC, 180 VA (Pilot Duty)
125 / 250 VDC, 28 VA (Pilot Duty)
2
Maximum load for each single output:
250 VAC, max. 3 A G.P.
30 VDC, 3 A G.P.
C300, R150 (Pilot Duty)
7 | 10
The changeover contacts (OUT9/OUT10) on terminal X32 are also intended for
connection to the same voltage circuits. The connection of different voltage
circuits is not permitted For voltages above 150 V, it is necessary that the
"COMMON" terminals of OUT9 and OUT10 have the same voltage potential.
NOTE
The interconnection of Class 2 outputs is prohibited.
Cable size
Connection
AWG
X31
310-319
24 - 12
X32
320-325
X33
330-335
X34
340-342
24 - 12
X36
360-363
, Class 2
X35
350-353
X38
380-385
24 - 16
X39
390-393
In the field-wiring area, provisions for wiring for Class 2 and Class 3 circuits must
meet the requirements for separation from Class 1 circuits in accordance with
Section 725 of the National Electrical Code, ANSI/NFPA 70 and Section 16 of the
Canadian Electrical Code. Separation from power and lighting circuits is required
for Class 2 by one of the following means:
a)
A permanent barrier shall be provided to separate the field installed Class 2
conductors of secondary circuits from all other circuits or;
b)
Provisions need to be made to route the Class 1 or power circuit conductors
in order to maintain a minimum 1/4-in (6.35 mm) separation from the
conductors of the Class 2 circuits.
E-File No. E218753
4.6

Assembly and connection

DANGER
Risk of electric shock!
Before connecting the accessories, switch off the supply voltage of the
controller!
Do not switch on the supply voltage of the controller again until the
installation of the accessories has been completed, the controller is
covered and no live parts can be touched.
ATTENTION
Connect connection terminals before connecting to the plug connectors! Only
thus is it possible to ensure a safe contact of the connection terminals to the
plug connectors.
FEIG ELECTRONIC GmbH
Lange Straße 4 | D-35781 Weilburg
Tel. +49 6471 3109-0 | Mail:
info@feig.de
Tightening
torque
NEC wiring
(mm
2
)
Lb-in
[NM]
(0.2 – 3.3)
3.5
(0.4)
Class 1
(0.2 – 3.3)
3.5
(0.4)
Class 2
(0.2 – 1.3)
2.2
(0.25)
Class 2
2019-10-15