DTK

3. Description of the appliance

°C
25.2
WORK
SET
SET
RST

4. Installation

25.2
°C
WORK
SET
SET
RST
possible fan
positions
possible vent
positions
228
A
B
314.00
Kickboard
326.00
Cup board floor
The digital temperature controller for Zip devices (Art. no.: 893159) is used when cup-
board temperatures are likely to exceed 30 °C and normal cupboard ventilation is not
available.
The digital controller operates independently of the undersink unit and will require a
separate 230 V GPO.
The controller is factory set to turn OFF at 33 °C and ON at 34 °C (recommended set-
tings).
The differential between ON and OFF is locked at 1 °C however the set temp is user
adjustable.
The current measured temperature is shown on the digital display in °C.
The following regulations must be observed:
• The rating plate and technical specifications
• Only intact and appropriate tools must be used
• Air inlet and the air outlet must be positioned at opposite ends of the same
cupboard to ensure the best possible ventilation
• It is important that controller and dual­fan are located in the warmest part (i.e.
upper half), of the same cupboard, where the undersink unit is located

Mounting the appliance

1. Attach the control unit as high as possible in the cupboard in which the Zip-device is
installed. The installation is possible on top of the cabinet or the sidewall.
Ensure that an electrical outlet is within reach of the connecting cable
(max. 130 cm).
2. If no air inlet is installed saw a cutout "A" for the inlet grille (sidewall / door) or a
cutout "B" for the inlet grille (cup board floor) according to the drawing, cover it with
the selected air inlet grille and secure it with screws.
3. For the dual-fan saw the cutout "A" according to the drawing at the intended posi-
tion.
Ensure that the connecting cable of the dual­fan can reach the control unit
(max. 145 cm).
4. Turn the brackets by 90° to the inside (see below), to allow the fan can be pushed
into the cutout "A" from the outside. Pay attention to the connecting cable of the fan,
when inserting the fan through the cutout.
5. After inserting the fan assembly, bend the brackets back through 90° to their origi-
nal position and secure the fan assembly with 4 screws.
6. Connect the dual-fan to the control unit via the connecting cable.
7. Plug the plug of the control unit into a 230 V outlet.