OH-Setup Windows Tool
The WISI tool named "WISI OH-Setup" (filename 'OHSetup.exe') has to be copied on a PC with opera-
ting system Windows XP / 7. An ethernet connection between this PC and the OH50A unit is required.
Start the program. Complete the four fields with the correct Ethernet MAC Address of the OH50A unit
(see label at OH rack: 00-03-98-...) and the wanted IP parameters (IP-Address, Network mask, Gateway).
Now press the button "Assign" for setting these parameters. The tool checks first, if the IP address is
valid and still free. Afterwards the IP parameters of the OH50A unit will be set and stored.
Please check the message in the lower status line of the window, if the assignment has succeeded or
not.
OH 41 Handset
While the handset is being used (Modul Menü) the web interface is disabled and displays
"Handset in use". After 60 seconds the handset automatically returns to the standby display.
The web interface is now enabled again. The handset has higher priority than the
web interface.