• 3rd Chamber contains a special ltrating substrat - a porous, rousted ceramic granulate that provides great
bacteria growth conditions that nally decompose organic substances dissolved in water including very
toxic to sh ammonia and nitrite.
MONTAGE & LAUNCH
Choose a at and stabile place that in the future can be easily reached for the purpose of the conservation.
As to maximize its potential, the pond lter should be placed in the full/mid shadow during the day so the
oating water does not get unnecessarily heat by the sun rays. Ensure Yourself that each drain valve is easily
reachable to open & close operations during the lter cleansing.
Put the attached air pump near the lter above the water level as to secure it from the sun rays and humidity.
Connect the pump with the aerator with the help of a hose on which there should be a check valve mounted
that prevents water from getting back to the air pump.
If You have a version of a lter without mounted drain valves.
Use the drain valve set and attached glue.
Degrease with an acetone or an extraction solvent and clean the glued part and then put a at layer of glue
on the surface. Then promptly put a valve in the output caring about appropriate positioning. The adhesive
sets quite quickly and therefore any further changes of the valve position are impossible.
If You have a pump version.
There is a special hose connector attached to the set which should be putted in
the lter inlet hole from below and then tighten the nut from the inside setting
all together. The gasket should be placed outside.
Before launching the lter, please check once again following points:
All hose and pipes connections are properly routed and set. Input and output lter, pumps and other elements
connections t tight.
Drain valves are closed.
Filtering layers in chambers are properly set.
Fill the lter with water.
Now you can run the ltration by following actions:
Firstly, switch the pump on and check if the water runs without disturbance through the lter and other
elements of the installation.
Check carefully if there are no leak-outs. Due to the production tolerance there may some dripping on the
connectors between the hose and the joints occur. In that situation we advise a te on tape PFTE usage.