TOUCHPANEL BEDIENUNG • TOUCH PANEL OPERATION
Button
ON
OFF
Function
ON (l). Enables all functions.
OFF (O). Turns off all functions on
control panel and remote control.
ON: Enables control panel functions
and remote control. Turns on flame
effect.
OFF: Disables control panel functions
and remote control. Turns off flame
effect
TIMER button: Controls timer settings
to turn off fireplace at selected time.
Settings range from 0.5 hours to 8
hours
FLAME button: Makes flame effect
dimmer and brighter.
NOTE: Flame effect stays on until po-
wer button is turned off. Flame effect
must be on for heater to turn on.
COLOR button: Makes the color
flame effect changing.
NOTE: color effect stays on until power
button is turned off. Color flame effect
must be on for heater to turn on.
NOTE: this fireplace is with memory
function for flame.
HEATER button: Turns heater on and
off.
NOTE: The heater only works when the
flame effect is on. If the flame effect is
off, the heater will not turn on.
NOTE: To prevent overheating, the
heater fan will blow cool air for 8-10
seconds before the heater turns on,
and after the heater turns off.
Action & Indication
1. Press once. Indicator light turns on. Power turns on. All
functions enabled.
2. Press again. Flame effect turns off. Unit goes to stand-
by. All functions turn off.
1. Press once. Indicator light turns on. Power turns on. All
functions enabled.
2. Press again. Flame effect turns off. Unit goes to stand-
by. All functions turn off.
1. Press once. Indicator light turns on. Timer is set to 0.5
hours.
2. Press again until desired setting is reached. Indicator
lights show setting.
1. Press once. Flame brightness effect gets changing.
2. Press again. until desired setting is reached.
1. Press once. Flame color effect gets changing.
2. Press again until desired setting is reached.
1. Press once. Indicator lights up.
Fan blows cool air for 10 seconds. 750W heater turns on
and blows warm air.
2. Press again. Indicator lights up.
1500W heater turns on and blows hot air.
3. Press again. Heaters turn off.
The fan blows cool air for 10 seconds to allow heater to
cool down, then turns off
www.mayergrill.com