Herunterladen Inhalt Inhalt Diese Seite drucken

Heater Stand And Location; Gas Requirements; Leakage Test - GGM Abbey.HS27.221. E Bedienungsanleitung

Terrassen-heizstrahler
Vorschau ausblenden Andere Handbücher für Abbey.HS27.221. E:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

The heater is primarily for outdoor use only. Always ensure that
adequate fresh air ventilation is provided.
Always maintain proper clearance to combustible materials, i.e. top 100 cm
and sides 100 cm minimum.
Heater must be placed on level firm ground.
Never operate heater in an explosive atmosphere like in areas where
gasoline or other flammable liquids or vapors are stored.
To protect heater from strong wind, anchor the base securely to the
ground with screws.
Use propane or butane gas only.
The pressure regulator and hose assembly to be used must conform to local standard codes.
The installation must conform to local codes, or in the absence of local codes, with the standard for the
storage and handling of liquid petroleum gases.
A dented, rusted or damaged propane tank may be hazardous and should be checked by your tank
supplier. Never use a propane tank with a damaged valve connection.
The propane tank must be arranged to provide for vapor withdrawal from the operating cylinder.
Never connect an unregulated propane tank to the heater.
Gas connections on the heater are leak tested at the factory prior to shipment. A complete gas tightness
check must be performed at the installation site due to possible mishandling in shipment or excessive
pressure being applied to the heater.
Make a soap solution of one part liquid detergent and one part water. The soap solution can be applied
with a spray bottle, brush or rag. Soap bubbles will appear in case of a leak.
The heater must be checked with a full cylinder.
Make sure the safety control valve is in the OFF position.
Turn the gas supply ON.
In case of a leak, turn off the gas supply. Tighten any leaking fittings, then turn the gas supply on and re-
check.
Never leak test while smoking.

HEATER STAND AND LOCATION

GAS REQUIREMENTS

LEAKAGE TEST

- 2 -
C E I LI N G
100 cm
Off
Igniter
Fortification of base to the ground

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Abbey.hs27.221. s

Inhaltsverzeichnis