Herunterladen Inhalt Inhalt Diese Seite drucken

Declaration Of Conformity - MESTIC Mini Chef MB-100 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 16
ENGLISH
Changing the gas bottle
1.
The gas cylinder may only be exchanged in the open air and away from combustible materials.
2.
Check the bottle tap and appliance tap are completely closed.
3.
Unscrew the gas pressure regulator from the gas bottle.
4.
Before reassembling the gas pressure regulator, check whether the rubber inlet ring is still present and
undamaged.
5.
Screw the swivel of the gas pressure regulator tightly onto the threads of the cylinder valve.
Check the burner operation
Check the burners and control valves at least once a year. If necessary, you must have this replaced by a recognized
installer.
Cleaning
All cleaning and maintenance work must take place with a cooled appliance and with a closed gas supply.
Note: before you start cleaning, make sure that the gas supply is shut off. The gas burners must be cleaned regularly
in order to prevent deposits of fat. If you remove parts during cleaning, ensure that these parts are correctly replaced.
Never use aggressive cleaning agents or tools, but professional cleaning agents or soapy water. Dry the parts and the
device thoroughly after cleaning.
Recycling
This product bears the selective sorting symbol for waste electrical and electronic equipment This
means that this
product must be handled pursuant to European Directive 2012/19/EU in order to be recycled or
dismantled to minimize its impact on the environment. For further information, please contact your local
or regional authorities. Electronic products not included in the selective sorting process are potentially
dangerous for the environment and human heath due to the presence of hazardous substances.

Declaration of conformity

Herewith, Gimeg Nederland B.V. declares that the MB-100 device complies with the basic requirements and other
relevant regulations referred to in the European Directive for gas-operated dressing appliances (2016/426 / EU) and
has been produced according to the following standards: EN498: 2012
You can request a complete declaration of conformity at the address stated on the reverse.
ITEM CODE
UR2802
DECLARED HEAT
2.5 kW (182g/h)
INPUT CAT.
I3b/p(30)
G30 BUTANE
INLET PRESSURE
G31 PROPANE
AT 30mbar
INJECTOR SIZE
0.77 mm
IDENTIFICATION
0063CR7811
CODE (PIN)
FOR USE OUTDOORS AND IN WELL VENTILATED AREAS READ THE
INSTRUCTION LITERATURE BEFORE USING THE APPLIANCE.
I3+(28-30/37)
I3B/P(50)
G30 BUTANE
G30 BUTANE
AT 28-30 MBAR
G31 PROPANE
G31 PROPANE
AT 37mbar
AT 50mbar
0.77 mm
0.7 mm
Country of destination:
I3+(28-30/37): BE,CH,CY,CZ,ES,FR,GB,GR,IE,IT,LT,LU,LV,PT,SK,SI.
I3B/P(30): BE,CY,DK,EE,FI,FR,HU,IT,LT,NL,NO,SE,SI,SK,RO,HR,TR,
BG,IS,LU,MT.
I3B/P(50): AT,CH,DE,SK,CZ.
WARNING: ACCESSIBLE PARTS MAY BE VERY HOT.
KEEP YOUNG CHILDEREN AWAY.
This appliance must be kept away from flammable materials during use.
Do not move the appliance during use.
Turn off the gas supply at the gas cylinder after use.
Do not modify the appliance.
0063
0063CR7811