ADD OR CHANGE A USER CODE (PRIVATE
FUNCTION)
#Master Code
Example: #11335577
Result: The User Code has been changed to 9999.
Note: Use Program 03 to delete User Codes.

INSTALLATION INSTRUCTIONS

Replacing an existing cam lock
1. Remove existing cam lock.
2. Place the template on the door, lining up the
16mm (5/8") spindle hole over the original cam
lock hole and mark the fixing hole.
3. Drill the 6mm (
4. Fit the V-Series™ to the door.
5. If required, use the packing pieces (supplied) to
centralise the lock.
6. Secure the lock to the door with the large
fixing nut.
7. Fit the upper fixing bolt.
8. Select and fit cam using the fixing nut and
locking washer. Lock nut in place by folding
over washer tabs.
9. Check operation:
Public Function: The lock is unlocked by
default. Enter 2244 to lock the lock. Re-enter
2244 to open.
Private Function: The lock is locked by default.
Enter 2244 to open.
10. If the lock is functioning correctly, change
the default Master Code and apply any
programming changes that you require.
New Installation
1. Place the template on the door and mark the
6mm (
hole.
Note: Ensure positioning of the fixing and
spindle holes allow enough clearance for the
selected cam.
2. Drill both holes.
3. Continue with steps 4-10 above.
02
User Code
/
1
4
/
") fixing hole and 16mm (
1
4
••
02
9999
") fixing hole.
••
/
") spindle
5
8