ELECTRONIC FAN
Velocità
Geschw.
Vitesse
Speed
FUNCTIONS
1) Temperature threshold regulating trimmer.
2) Operating mode selector switch:
MANUAL:
> full speed operation
AUTO
MATIC
:
> full speed operation when the temperature is
higher than about 50 C°.
WARNING
Please respect the power supply voltage (12V
the polarity (black = negative, red = positive) and
connect the device to line protected by
INSTALLATION INSTRUCTIONS
Install the fan in the upper grille of the refrigerator, in
order to allow the air circulation from indoor to
outdoor.
Install the fan in the best possible way, depending
on the type of the grille, with the sensor towards the
4
0
I
>28°
<35°
>50°
28°
35°
a
a f
use using
,
II
1
2
3
> reduced speed operation when the temperature
is between the threshold set in advance (28 /
35°C) and about 50 C°.
3) Operating signalling LED:
green: fan powered.
yellow: automatic operation at reduced speed.
r
ed
:
manual or automatic operation at full
speed.
),
cables with a suitable cross-section (minimum cross-
section 1mm²).
inside; To install the control panel use the bottom of
the box like a drilling template (a 13mm hole is
needed for the passage of the connector).
12V
+
-