Herunterladen Inhalt Inhalt Diese Seite drucken

Power Management; Power Requirements - Indel B TB Steel Serie Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 56
TB STEEL SINGLE DOOR

POWER MANAGEMENT

POWER REQUIREMENTS

The appliance is designed to operate on AC and DC voltage inputs.
AC input
DC input
For optimum performance and efficiency, it is important that the appliance has a reliable 15A fuse protected
DC supply in good condition. Direct connection to the battery is recommended and reduces the risk of
voltage dropping to the appliance.
It is recommended that the correct sized Automotive Electrical Cable is used for the direct connection and
that this includes a 15A fuse; do not use resettable circuit breakers. It is important that the correct cable
size is used for the installation of the DC supply as over distance the voltage can decrease if the incorrect
sized cable is being used.
DISTANCE CABLE GAUGE FOR DC INPUT
4.5m or less
4.6m and over
TB STEEL SINGLE DOOR_27-04-2018
220-240V AC at 50Hz
12V or 24V DC
2.1mm
(AWG14)
2
3.3mm
(AWG12)
2
ENGLISH
19

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis