MR-CI4
1108401332
Montagehinweis für den Installateur
de
Mounting note for the installer
en
Notice d'installation pour l'installateur
fr
Open Energy Management Equipment 34TZ
de
Nur Kupferleiter verwenden
en
Use copper conductors only
fr
Utiliser uniquement des fils de cuivre
C1| Anschlussbild
Connection diagram
Raccordements
I4 U4 4- I3 U3 3-
A1
24 V AC/DC
A1
GND
A2
A2
B+
BUS B+
B+
A-
A-
BUS A-
1- U1 I1 2- U2 I2
C2|Prinzipbild
Principle diagram
Schéma de principe
A1/ +24 V
I1
D
24 V
U1
A2/ GND
1-
BUS B+
Modbus RTU
I2
on RS-485
BUS A-
U2
2-
Voltage 0-10 V
I3
U3
No function
3-
0..20 mA
I4
U4
A
4..20 mA
4-
24V
24V
0
+24V
+24V
GND
GND
x10
B +
x1
B+
0
-
-
A
A
K1
K2
K3
K4
METZ CONNECT GmbH | Im Tal 2 | 78176 Blumberg | Germany
Phone +49 7702 533-0 | Fax +49 7702 533-433
Weitere Dokumentation siehe / additional documentation see / documentation supplémentaire voir www.metz-connect.com
de
DEUTSCH
A| Sicherheitshinweise
GEFAHR
Gefahr bedeutet, dass bei Nichtbeachtung Lebens-
gefahr besteht, schwere Körperverletzungen oder
erhebliche Sachschäden auftreten können.
WARNUNG
Für die Montage, Inbetriebnahme und den Einsatz
des Geräts sind die jeweils länderspezifisch gültigen
Arbeitsschutz-, Unfallverhütungs- und Sicherheits-
bestimmungen einzuhalten und folgendes zu
beachten:
• Facharbeiter oder Installateure werden darauf
hingewiesen, dass sie sich vor der Installation
oder Wartung der Geräte vorschriftsmäßig ent-
laden müssen.
• Montage-, Wartungs- und Installationsarbei-
ten an den Geräten dürfen grundsätzlich nur
durch qualifiziertes Fachpersonal durchgeführt
werden.
• Qualifiziertes Fachpersonal im Sinne dieser
Anleitung sind Personen, die mit den beschrie-
benen Geräten vertraut sind und über eine
ihrer Tätigkeit entsprechenenden Qualifikation
verfügen.
B| Beschreibung
Das Modbus-Modul mit 4 analogen Eingängen wurde für
dezentrale Schaltaufgaben entwickelt. Es können Ströme und
Spannungen, von z. B. aktiven Temperaturfühlern, elektrischen
Lüftungs- und Mischklappen, Ventilsteuerungen usw., erfasst
werden. Jeder Eingang kann per DIP-Schalter auf der Front-
seite entweder als Strom- oder Spannungseingang eingestellt
werden.
Mit einem Modbus-Master können die Eingänge über Stan-
dard-Register abgefragt werden. Die Einstellung der Modu-
ladresse, Bitrate und Parität erfolgt über zwei Drehschalter auf
der Frontseite oder per Software
Geeignet zur dezentralen Montage auf Tragschiene TH35 nach
IEC 60715 in Elektroverteilern.
C| Technische Daten
Protokoll
Modbus RTU
Adressbereich
00 bis 99
Busschnittstelle
RS485 (Zweidrahtbus)
Übertragungsrate
1200 bis 115200 Bit/s
Betriebsspannung
24 V AC/DC ± 10 % (SELV)
Stromaufnahme
25 mA (AC) / 10 mA (DC)
Einschaltdauer relativ
100 %
Eingänge
4 x analog
Eingang / Spannung (U1-U4)
0 V bis 10 V DC
Eingang / Auflösung
1 mV (0 bis 100 %)
Eingang / Fehler
10 mV
Eingang / Strom (I1-I4)
0 (4) bis 20 mA DC
Eingang / Auflösung
2 µA
Eingang / Fehler
20 µA
Anzeige
LED grün, rot
Abmessungen B x H x T
35 x 69,3 x 60 mm
Gewicht
84 g
Betriebstemperaturbereich
-5 °C bis +55 °C
Lagertemperaturbereich
-20 °C bis +70 °C
Schutzart Gehäuse / Klemmen
IP40 / IP20
Beschreibung
vorhandene Betriebsspannung
K1
Empfangen eines gültigen Kommandos
vom Master
K2
eingestellte Adresse „0"
Kommunikationsfehler, Parity-ERROR
K3
Kommunikationsfehler, CRC-ERROR
Kommunikationsfehler, Framing-ERROR
K4
unvollständige Frames
Eingang aktiv
HINWEIS
Zusätzliche Informationen, Dokumenta-
tionen und das Modbus Konfigurations-Tool
stehen zum Download unter
www.metz-connect.com bereit.
en
ENGLISH
A| Safety instructions
DANGER
Danger means that non-observance may cause
risk of life, grievous bodily harm or heavy material
damage.
WARNING
Follow the applicable country-specific safety at
work rules, the regulations for the prevention of
accidents and safety regulations when mounting,
bringing into service and using the device and
observe the following:
• Technicians and/or installers are informed that
they have to electrically discharge themselves as
prescribed before installation or maintenance of
the devices.
• Only qualified personnel is allowed to do moun-
ting, maintenance and installation work on the
devices.
• Qualified personnel in the sende of these inst-
ructions are persons who are well versed in the
use and installation of such devices and who
possess the necessary qualification for their job.
B| Description
The Modbus module with 4 analog inputs was developed for
decentralized switching tasks. It is suitable for detecting cur-
rents and voltages of, for example, active temperature sensors,
electrical vent and mixing valves, valve positions, etc. Each
input can be set as current or voltage input by DIP switches on
the front.
The inputs can be scanned with standard registers via a Mo-
dbus master. Module address, bit rate and parity are set with
two rotary switches on the front or by software.
Suitable for decentralized mounting on TH35 rails according to
IEC 60715 in electrical distribution cabinets.
C| Technical Data
Protocol
Address range
Bus interface
Transmission rate
Operating voltage
Current consumption
Relative duty cycle
Inputs
Input / voltage (U1-U4)
Input / resolution
Input / error
Input / current (I1-I4)
Input / resolution
Input / error
Display
Dimensions (W x H x D)
Weight
Operating temperature range
Storage temperature range
Ingress protection
for housing / terminal blocks
LED Anzeige
Description
Grüne LED
Operating voltage is present
Grüne LED
Reception of a valid command
erlischt kurz
from the Master
Rote LED
Address setting "0"
Rote LED
Communication error, parity ERROR
Rote LED
Communication error, CRC ERROR
Rote LED
Communication error, framing ERROR
Rote LED
Uncomplete frames
Gelbe LED
Input active
NOTE
Additional information, documentations
and the Modbus configuration tool are
available as download at
www.metz-connect.com
fr
A| Avis de sécurité
DANGER
Danger signifie que de la non observation des
consignes peut entraîner un risque mortel ou des
dommages matériels importants.
AVERTISSEMENT
Pour le montage, la mise en service et l'utilisation
de l'appareil il faut respecter les règlements en
vigueur selon le pays concernant la protection au
travail, la prévention des accidents et la sécurité et
de respecter aussi les avis suivants :
• Des travailleur qualifiés ou installateurs sont
avertis qui'il est nécessaire de se décharger
correctement de l'électricité avant d'installer ou
d'entretenir l'appareil.
• Seul du personnel qualifié est autorisé à effectu-
er le montage et l'installation, voir paragraphe
personnel qualifié.
• Du personnel qualifié au sens de ces instructions
sont des personnes qui sont familiers avec les
appareils décrits et dont le qualifications pro-
fessionnelles sont en rapport avec leur travail.
B| Description
Le module Modbus avec 4 entrées analogiques a été conçu
pour les tâches de commutation décentralisées. Il convient
pour détecter les courants et les tensions, par ex. sur les cap-
teurs de température actifs, les trappes d'aération, les volets
mélangeurs et les réglages de vannes électriques etc. Chaque
entrée se laisse régler comme entrée de courant ou entrée de
tension par les commutateurs DIP sur la face avant.
Un maître Modbus permet d'interroger les entrées via des
registres standards. L'adresse du module, le débit binaire et la
parité sont réglés par deux commutateurs rotatifs sur la face
avant ou par logiciel.
Convient au montage décentralisé sur rail TH35 selon IEC
60715 dans des répartiteurs électriques.
C| Données techniques
Modbus RTU
Protocole
00 to 99
Plage d'adresses
RS485 (two-wire bus)
Interface bus
1200 to 115200 bit/s
Vitesse de transmission
24 V AC/DC ± 10 % (SELV)
Tension de service
25 mA (AC) / 10 mA (DC)
Consommation électrique
100 %
Taux de marche relatif
4 x analog
Entrées
0 V to 10 V DC
Entrée / tension (U1-U4)
1 mV (0 to 100 %)
Entrée / résolution
10 mV
Entrée / erreur
0 (4) to 20 mA DC
Entrée / courant (I1-I4)
2 µA
Entrée / résolution
20 µA
Entrée / erreur
Green, red LED
Affichage
35 x 69.3 x 60 mm
Dimensions L x H x P
95 g
Poids
-5 °C to +55 °C
Plage des températures
-20 °C to +70 °C
de service
Plage des températures
IP40 / IP20
de stockage
Indice de protection
boîtier / borniers
LED display
Description
Green LED
Tension d'alimentation présente
Green LED turns
Récéption d'une commande valable du
off briefly
Maître (Master)
Red LED
Red LED
Adresse réglée « 0 »
Red LED
Erreur de communication, Parity ERROR
Red LED
Erreur de communication, CRC ERROR
Red LED
Erreur de communication,
Framing ERROR
Yellow LED
Trames (Frames) incomplèts
Entrée active
NOTICE
FRANÇAIS
Modbus RTU
de 00 à 99
RS485 (bus à deux fils)
1200 à 115200 bit/s
24 V CA/CC ± 10 % (SELV)
25 mA (CA) / 10 mA (CC)
100 %
4 x analogique
de 0 V à 10 V CC
1 mV (0 à 100 %)
10 mV
de 0 (4) à 20 mA CC
2 µA
20 µA
DEL verte, rouge
35 x 69,3 x 60 mm
95 g
de -5 °C à +55 °C
de -20 °C à +70 °C
IP40 / IP20
Affichage
par DEL
DEL verte
La DEL verte
s'éteint
brièvement
DEL rouge
DEL rouge
DEL rouge
DEL rouge
DEL rouge
DEL jaune
Des informations et documentations
supplémentaires ainsi que l'outil de
configuration Modbus sont disponibles
pour téléchargement à
www.metz-connect.com
loading

Inhaltszusammenfassung für Metz CONNECT MR-CI4

  • Seite 1 à www.metz-connect.com METZ CONNECT GmbH | Im Tal 2 | 78176 Blumberg | Germany Phone +49 7702 533-0 | Fax +49 7702 533-433 Weitere Dokumentation siehe / additional documentation see / documentation supplémentaire voir www.metz-connect.com...
  • Seite 2 All other settings = 0 = Broadcast Tous les autres réglages = 0 = Broadcast METZ CONNECT GmbH | Im Tal 2 | 78176 Blumberg | Germany Phone +49 7702 533-0 | Fax +49 7702 533-433 Weitere Dokumentation siehe / additional documentation see / documentation supplémentaire voir www.metz-connect.com...