Herunterladen Inhalt Inhalt Diese Seite drucken

Utilization; Water Connection - Polytropic Advance S Betriebsanleitung

Vorschau ausblenden Andere Handbücher für Advance S:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Utilization

Water connection

After having connected the heat pump to the pool water circuit system trough a suitable by-
pass and having made the electrical connections by a qualified engineer, please verify the
following points:
• Appliance is in a horizontal position and on a solid ground.
• Water circuit is primed (full of water): no air inside the tubes or the heat pump tank.
• Water circuit is well connected (no leaks and no chance of injury due to badly fitted
hydraulic couplings).
• Electrical circuit is well connected (all cables tightened correctly at terminals and
intermediate circuit breaker), insulated and earthed correctly.
• The installation requirements described previously are strictly adhered to.
• Ambient temperature is between :
• + 5 and
• - 5 and
• Water temperature is between 15 and 30°C (50°F and 86°F).
• You can then start up your machine. Follow the instructions below in the given order each
time you start up the pool heat pump, especially at the beginning of the swim season:
• Open the three by-pass valves and then half close the settings valve
• Start the pool pump
• Turn on the pool heat pump with the on/off switch (turn it to « I »).
• Check the machine to make sure that it starts only together with the filtration pump: If the
filtration pump is not working, the "flow" LED will stop lighting. If it doesn't detect the water
flow, please see chapter « water flow switch setting ».
+ 35°C
(Advance temperature range)
+ 35°C
(Master temperature range)
By-pass diagram
- 42 -

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis