EN
A damaged luminaire must not be used; voltage must be disconnected from it and it must
be repaired.
An unstable electrical grid may damage the electronic components of the luminaires.
Temperature and the quality of the supply voltage affect the service life of the control gear.
The estimated failure rate is 0.2% per each 1,000 operating hours at the luminaire's maximum
allowed ambient temperature. However, a failure rate of 10% remains within normal limits.
Transients and voltage spikes significantly reduce the service life, as does an unclean
supply voltage.
The luminous emittance of LED luminaires has a tolerance of ±10%. The luminous flux of
LED light sources decreases over their service life, just like that of traditional light sources.
When an old LED luminaire is replaced with a new one, the difference in luminous emittance
may be evident to the naked eye due to the better lighting power of the new luminaire.
The colour temperature of the luminaire may also change.
The product is covered by the Waste Electrical and Electronic Equipment Directive 2012/19/EC
(WEEE), and must be properly recycled at the end of its service life.
CLEANING
Before cleaning, voltage must be disconnected from the luminaire. The electronic
components and connectors must not be exposed to moisture.
The exterior surfaces of the luminaire should be cleaned of dirt occasionally, thus ensuring
its effective operation. Regular cleaning is important for optimal luminous emittance.
A thick layer of dust on top of the luminaire will increase its internal temperature. This may
reduce the service life of the luminaire.
If necessary, the luminaire can be cleaned with neutral soap solutions (pH 7), for example
dishwashing liquids. They are also suitable for cleaning the glass or the polycarbonate cover.
Dilute the cleaning agent with water, and use a cloth rag or a sponge for cleaning.
Do not spray the cleaning agent directly onto the surface of the luminaire, as it may be
difficult to remove from the protective cover.
Do not use a pressure washer to clean the luminaire.

FILTER REPLACEMENT

In a normal industrial environment, the recommended replacement interval of the filter
is around 4 to 5 years. Depending on the conditions, if dirt accumulates on the cover glass,
the filter should also be replaced while cleaning the cover glass.