INSTRUCTION
SIR-PW
IN20059 REV. A, 2022-02-10
Caution! Read and understand the instruction before using the product.
Function
SIR-PW detects motion within an area and sends signals to a receiver to
activate for example ventilation or heating. It is designed to work with a
Industrietechnik wireless receiver with Modbus communication.
Technical Data
Supply voltage
CR123A 3V lithium battery, 1500 mAh x 1 (included at
delivery)
Battery life
6 years
1
Range, detection
12 m over 110° angle (2 m mounting height)
Range,
Up to 300 m (open space)
communication
Frequency
868 MHz
Ambient
-10...+50 °C
temperature
Ambient humidity
Max. 85 % RH, non-condensing
Protection class
IP20
Dimensions, external
64 x 94 x 42 mm
(WxHxD)
1. Battery life is calculated at an average of 20 activations per day
SIR-PW
Installation
The detector is equipped with a tamper switch on the back cover. When the
detector is mounted correctly, the tamper switch will be compressed. When
the detector is removed from the back cover or the wall, the tamper switch
will activate and the detector will send a signal to the receiver.
Detection area
2 m
A
1 m
12 m
B
110°
Figure 1 Detection area, A = Side view, B = Top view
Choosing position for detector mounting
For best coverage, the detector should be mounted on a height of 2 meters
above the ground.
Mounting
Wall mounting
1. Open the cover by removing the fixing screw at the bottom of the
detector.
2. Break through the desired knockouts on the back cover.
3. Use the knockout holes to screw the detector to the wall.
This method will enable the tamper switch function.
Corner mounting
With triangular bracket:
1. Break through the knockouts on the bracket.
2. Mount the bracket in the corner with the two pointing sticks on top
facing you.
1 (6)
3. Snap on the detector to the bracket
4. Screw the cover back on.
This method will enable the tamper switch function.
With knockouts in housing:
1. Open the cover by removing the fixing screw.
2. Break through the knockouts on the slanted sides of the housing.
3. Mount the detector in the corner.
4. Screw the cover back on.
The tamper switch will not be enabled with this mounting method.
12 m
A
1
Figure 2 A = Front, B = Back, C = Bracket
Number
1
2
3
4
Note! Do not mount the detector:
– Where the view is obstructed by e.g. curtains, ornaments etc.
– Directly facing a door contact (DCW), since the signals can interfere
– In direct sunlight
– Where the temperature can rapidly change, e.g. in an area with an air
condition unit
– Directly facing heat sources, e.g. boilers, open fires
– Above a radiator
– Where there are moving objects in the detection area, e.g. curtains
B
2
C
3
4
Description
Connection/Test button/LED light
Battery insulator
Tamper switch
Triangular bracket for corner mounting with back tamper
protection

Werbung

loading

Inhaltszusammenfassung für Industrie Technik SIR-PW

  • Seite 1 Number Description 110° SIR-PW detects motion within an area and sends signals to a receiver to Connection/Test button/LED light activate for example ventilation or heating. It is designed to work with a Figure 1 Detection area, A = Side view, B = Top view Battery insulator Industrietechnik wireless receiver with Modbus communication.
  • Seite 2: Installazione

    Otherwise adjust the mounting of the detector. Funzione SIR-PW rileva movimento all'interno di una zona e fornisce un segnale a un Handling ricevitore per attivare, ad esempio, la ventilazione o il riscaldamento. Il sensore è...
  • Seite 3: Messa In Servizio

    – Dove la temperatura può cambiare rapidamente, ad es. in una zona con un condizionatore d'aria – Direttamente di fronte a fonti di calore, ad es. caldaie, fuochi aperti – Sopra un radiatore – Dove ci sono oggetti in movimento nell'area di rilevamento, ad es. tende SIR-PW 3 (6)
  • Seite 4: Technische Daten

    Bei dieser Montageart wird der Sabotagekontaktnicht aktiviert. Funktion SIR-PW Erkennt Bewegung innerhalb eines Bereiches und sendet Signale an 12 m einen Empfänger, um beispielsweise die Heizung oder Lüftung zu aktivieren. Das Gerät wurde für die Nutzung mit einem Industrietechnik Funkempfänger mit Kommunikation via Modbus entwickelt.
  • Seite 5: Bedienung

    Bedienung Fonction Im normalen Betriebsmodus leuchtet die LED nicht auf, wenn der SIR-PW détecte les mouvements dans un périmètre déterminé et envoie des Bewegungsmelder aktiviert wird. signaux à un récepteur pour activer la ventilation ou le chauffage, par exemple. Il est conçu pour fonctionner avec un récepteur sans fil Blinken: Industrietechnik qui dispose d’une communication Modbus.
  • Seite 6: Mise En Service

    Marchez vers la zone de Support triangulaire pour l’installation en coin avec auto- protection à l’arrière détection de votre choix pour vérifier que la plage est adaptée. Dans le cas contraire, ajustez l’installation du détecteur. SIR-PW 6 (6)