I N S T R U C T I O N M A N UA L
1.
Function keys
2.
Digital Display
3.
Battery Compartment
4.
Beam
5.
External Jaws
D E L I V E RY
•
Digital Rotor Gauge
•
1 piece 3 Volt button cell
T E C H N I C A L DATA
Measure Range:
Measurable Jaw Depth:
Resolution:
Accuracy:
Display:
Material:
Power-Off:
Battery:
B AT T E RY R E P L AC E M E N T :
Once Display start not turning on or fl ashing:
•
Pull out the battery compartment holder and remove the old battery. Never try to apply force or pry.
•
Replace the new battery in the battery compartment holder. Pay attention to the correct polarity.
•
Insert the battery holder into the battery compartment.
•
Please recycle the used batteries at a proper collection center.
F U N C T I O N K E YS :
•
ON/O Key: 1x press turn unit on / press again set to zero.
Automatic Power-Off after approximate 2 minutes.
•
mm/in/F Key: switch between inch, metric and inch fractions.
•
HOLD Key: Display value is held
C A R E A N D M A I N T E N A N C E
•
Keep the instrument clean and dry.
•
Avoid shocks or impacts.
•
Avoid strong magnetic fi elds.
•
Clean instrument with a soft cloth.
DO NOT use any type of solvent.
DO NOT immerse instrument in liquid.
5
4
0 - 80 mm / 0 - 3.2 "
28 mm / 1.10 "
0,01 mm / 0.0005 "
± 0,025 mm / ± 0.001 "
LCD display
Solid hardened stainless steel
Automatic Power-Off
1 piece CR2032. 3 Volt
7 2 3 4 7 L
3
2
1
5