PR3002 POWER REPEATER
Wiring instructions
EN
This instruction sheet follows on from the C100924 controller instruction to complete the wiring.
NOTE: The instructions are for wiring RGBW product (4 LEDs - red/green/blue/white).
If wiring RGB product to power repeater outputs, the only difference is that there is no white LED and the output terminals marked "W" are
unused.
1. Refer to the LED wiring instructions and connect the LED circuits to the power repeater outputs. On each power repeater there are two output
terminals for each colour. This allows either one or two circuits to be connected.
e.g. the maximum length for a single piece of RGBW strip is 5 metres. One 5 metre length can be connected to one set of terminals and another 5
metres to the other set of terminals, as in Diagram 1.
2. a. Refer to Diagram 2 to determine the wattage load for each power repeater.
e.g. 5 metres of RGBW strip = 75W load (100W driver required).
10 metres RGBW strip = 150W load (150W driver required).
b. Connect the drivers to the power repeaters as shown in Diagram 1.
3. For wiring PR3002 power repeaters and PR3011 power repeaters to the same controller, see Diagram 3.
4. Refer to the 24V DC driver instructions to connect the drivers to the mains supply.
5. If using remote control, refer to the remote control instructions for programming and operating details.
t +44 (0) 1604 495 151 f +44 (0) 1604 495 095
EN
e sales@collingwoodgroup.com w collingwoodlighting.com
t +33 (0) 4 816 816 10 f +33 (0) 4 816 816 11
FR
e ventes@collingwoodgroup.com w collingwoodlighting.com
All manuals and user guides at all-guides.com
t +49 (0)89 411123 777 f +49 (0)89 411123 778
DE
e verkauf@collingwoodgroup.com w collingwoodlighting.com
CWI 8079 V1

Werbung

loading