Herunterladen Inhalt Inhalt Diese Seite drucken

Dometic Gale 12V Pump Bedienungsanleitung Seite 5

Elektrische luftpumpe
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 7
Please read these instructions carefully and follow all instructions, guidelines, and warnings included in this
product manual in order to ensure that you install, use, and maintain the product properly at all times. These
instructions MUST stay with this product.
By using the product, you hereby confirm that you have read all instructions, guidelines, and warnings carefully
and that you understand and agree to abide by the terms and conditions as set forth herein. You agree to use
this product only for the intended purpose and application and in accordance with the instructions, guidelines,
and warnings as set forth in this product manual as well as in accordance with all applicable laws and regula-
tions. A failure to read and follow the instructions and warnings set forth herein may result in an injury to yourself
and others, damage to your product or damage to other property in the vicinity. This product manual, including
the instructions, guidelines, and warnings, and related documentation, may be subject to changes and
updates. For up-to-date product information, please visit documents.dometic.com, dometic.com.
Explanation of symbols
!
WARNING!
Safety instruction: Indicates a hazardous situation that, if
not avoided, could result in death or serious injury.
!
CAUTION!
Safety instruction: Indicates a hazardous situation that, if
not avoided, could result in minor or moderate injury.
A
NOTICE!
Indicates a situation that, if not avoided, can result in prop-
erty damage.
I
NOTE
Supplementary information for operating the product.
Safety Instructions
!
WARNING! Failure to obey these warnings could
result in death or serious injury.
Electrocution hazard
Do not operate the electric air pump if it is visibly dam-
aged.
If this electric air pump's power cable is damaged, it must
be replaced by the manufacturer, a service agent or a sim-
ilarly qualified person in order to prevent safety hazards.
This electric air pump may only be repaired by qualified
personnel. Improper repairs can lead to considerable haz-
ards.
Do not use the electric air pump in wet conditions or sub-
merge in any liquid. Store in a dry place.
!
CAUTION! Failure to obey these cautions could result
in minor or moderate injury.
Electrocution hazard
Before starting the electric air pump, ensure that the
power cable and the plug are dry and the plug is free of
rust or foreign matter.
Disconnect the electric air pump from the power supply
before each cleaning and maintenance
after every use
Risk of injury
This device is not intended for use by persons (including
children) with reduced physical, sensory or mental capa-
bilities, or lack of experience and knowledge, unless they
have been given supervision or instruction concerning
use of the device by a person responsible for their safety.
Keep children and pets away from the electric air pump
whilst operation.
Do not direct air stream at face or body.
Observe the recommended air pressure.
Cleaning and user maintenance may not be carried out by
unsupervised children.
A
NOTICE! Damage hazard
Check that the voltage specification on the data plate
corresponds to that of the energy supply.
EN
Do not place the device near naked flames or other heat
sources (heaters, direct sunlight, gas ovens etc.).
Do not let the device operate unattended.
Never pull the plug out of the socket by the cable.
Scope of delivery
Component
Electric air pump
Air hose
Nozzle adapter
Intended use
The electric air pump is intended to be used for inflatables such as awning
tents and tents. The electric air pump is designed to be operated from a
DC power supply socket of a vehicle.
This product is only suitable for the intended purpose and application in
accordance with these instructions.
This manual provides information that is necessary for proper installation
and/or operation of the product. Poor installation and/or improper oper-
ating or maintenance will result in unsatisfactory performance and a possi-
ble failure.
The manufacturer accepts no liability for any injury or damage to the prod-
uct resulting from:
Incorrect assembly or connection, including excess voltage
Incorrect maintenance or use of spare parts other than original spare
parts provided by the manufacturer
Alterations to the product without express permission from the manu-
facturer
Use for purposes other than those described in this manual
Dometic reserves the right to change product appearance and product
specifications.
Technical description
The electric air pump is equipped with a pressure induction system and
switches off automatically as soon as the preset pressure is achieved. The
pressure induction system operates with an error margin of ± 0.5 psi.
Using the electric air pump
A
NOTICE! Risk of overheating
Make sure that the electric air pump is sufficiently venti-
lated during operation.
Do not operate the electric air pump continuously for
longer than 15 min as the motor may overheat.
Allow the electric air pump to cool down for 30 min after
15 min of continuous use.
I
NOTE
If no buttons have been pressed for 30 sec, the LCD dis-
play will go into standby mode. Press any button to reac-
tivate.
At first it will take time for the pressure reading on the
LCD display to increase. This is normal, as a large amount
of air is initially required to fill the air frame before a signif-
icant change in pressure is detected.
➤ Proceed as shown to use the electric air pump (fig. 1, page 3 to
fig. 0, page 4).
4445103533
Quantity
1
1
6
5

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading