Herunterladen Inhalt Inhalt Diese Seite drucken

Operation; Maintenance; Troubleshooting - JBM 53796 Bedienungsanleitung

Tragbarer ozongenerator 600 mg/h (12v/220v)
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 8
EN
INSTRUCTION MANUAL
TECHNICAL SPECIFICATIONS
Power consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15W
Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12V, 220V
Air volume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15m³/h
Ozone production . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 600mg/h
Ion output. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3x10⁶/cm³
Product size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180x130x80mm
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2,30kg
PRODUCT'S PRESENTATION
This product has been designed to disinfect the
air in rooms, using ozone (O3) to oxidize almost
any particle (including viruses, bacteria, organic
and inorganic compounds).
SAFETY INSTRUCTIONS
For sterilization, please only use in unoccupied
space.
Ozone with high concentration has adverse
effects on human health. Therefore, the use of
ozone for air disinfection is generally not recom-
mended if people are around.
Therefore, air disinfection using ozone should
be restricted to unoccupied room only.
It is important that the ozone air purifier be pro-
perly grounded to avoid potential shock.

OPERATION

Press the power on button to turn on the ge-
nerator.
When you press the button, the generator will
automatically set the 60min. operation.
If you need a different setting, please again the
button to select the 30/30 min. or the HOLD se-
tting.
Operation mode description:
• 60 min.: It will stop after 60 minutes working.
• 30/30 min.: It will work 30 minutes, then stop
30 minutes, then will work 30 minutes and
so on.
• HOLD: It will not stop working.
After choosing the operation mode, the indicator
will flash for 6 seconds. Then, the light will stop
flashing.
If you want to turn off the generator, press the
power on button and the generator will stop wor-
king.
Before entering in a disinfected area, you should
wait for approximately one hour to make sure
ozone levels are not harmful to human health.
To know the exact concentration of ozone in the
air, you can use an ozone meter (REF.53802).
If you need to enter the area while disinfecting
it, make sure you wear suitable personal protec-
tive equipment.

MAINTENANCE

Ozone plate:
Clean the ozone plate about once every month
with a cloth to remove the dust.
Air-filter:
Air-filter is washable. You can clean if dirty.

TROUBLESHOOTING

If you suspect a problem with your unit please
proceed with the following:
1. Unit is plugged in properly and turned on.
2. Wall outlet is active.
3. Ozone plate is clean and dry without any
cracks.
If the fan is still not operating or no buzzing
sound is detected when operating, please con-
tact with your provider.
· 4 ·
REF. 53796

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis