Herunterladen Diese Seite drucken

Installation Procedure - NERI Nebula Installationsanleitung

Werbung

INSTALLATION PROCEDURE

INSTALLATION INFORMATION
Installation must be carried out in
accordance with national standards.
The fixture must only be used when
complete with safety screen. If the screen
is damaged or broken, the fixture must not
be used. Restore the original conditions
before reusing. The fixture is installed
under CL II protection standards,
particular care must be taken while
assembling to ensure that exposed metal
parts do not come into electrical contact
with parts of the electrical installation
connected to a protection conductor. This
light fixture must be installed only for the
use for which it was designed, namely for
the illumination of outdoor spaces.
Any other use must be considered to be
improper and dangerous, and the
manufacturer cannot be held liable for
any damage caused by improper and
unreasonable use.
For more information, please see the
supplementary instructions on the
website at
www.neri.biz/installationguides
Handle the products with extreme care as
impact can cause visible damage.
Installation - H Bollard 1m
Unscrew the two screws (M5) (Fig. 1) at
the base of the lighting fixture and lift the
outer frame (Fig. 2). The direction of light
emission can be modified by rotating the
lower frame (allowable rotation is ±90°)
(Fig. 3-4). Secure the lower frame with two
screws - 6 to 8 mm- (Fig.5) (fixing screws
not supplied).
Electrical Connection - H Bollard 1m
Connect the power cable (A - Fig. 6-8-9). In
case of using
RGBW source connect the DMX cable (B -
Fig. 7-8-9).
If the external flexible cable of this
appliance is damaged, it must be replaced
only by the manufacturer, its service
agent, or a qualified person to avoid
danger.
Return the outer frame to the
starting position (Fig. 10) and tighten the
two screws (M5) (fig. 11).
Installation - H Bollard 2.74m
Unscrew the four screws (M5) (Fig. 12) at
the base of the lighting fixture and lift the
outer frame (Fig. 13).
·
10
Neri Spa
Guida all'installazione
The direction of light emission can be
modified by rotating the lower frame
(allowable rotation is ±90°) (Fig. 14-15).
Secure the lower frame with three anchors
bolts to the foundation plinth (Fig. 16)
(anchors and bolts are not supplied).
Electrical Connection - H Bollard 2.74m
Connect the power cable
(A - Fig. 17-19-20). In case of using
RGBW source connect the DMX cable
(B - Fig. 18-19-20).
If the external flexible cable of this
appliance is damaged, it must be replaced
only by the manufacturer, its service
agent, or a qualified person to avoid
danger.
Return the outer frame to the
starting position (Fig. 21) and tighten the
two screws (M5) (fig. 22).
Adjusting the inclination of the lighting
fixture
The standard inclination of the lighting
fixture is 0°. To adjust the inclination with
a value different from the standard,
unscrew the two screws (M5) (Fig. 23) and
lift the upper frame (Fig. 24). Loosen the
two screws (M4) (Fig. 25) and rotate the
lighting fixture by the desired value.
The allowed free adjustment is
±45° (Fig. 26-27-28). Tighten the two
screws (M4) (Fig. 29), position the upper
frame in the initial position (Fig. 30) and
tighten the two screws (M5) (Fig. 31).
Anti-glare devices
For the installation of devices
anti-glare follow the instructions below:
Unscrew the end ring located at the end of
the lighting fixture (Fig. 32) and screw on
the ring supplied with the accessory
(Fig. 33). Bring the anti-glare device closer
to the base of the ring, position it in the
desired configuration and tighten the two
screws (M4) (Fig. 34-35). The anti-glare
device is available in 30° and 45° versions.
Refractor screens
Follow the instructions below to install the
refractor screens:
Unscrew the end ring located at the end of
the lighting fixture (C) (Fig. 36) and screw
on the ring supplied with the accessory
(D). Place the gasket (E) and refractor
screen (F) in place and screw the end ring
(C) back on (Fig. 37-38).
·
·
Installation guides
Guide d'installation
MAINTENANCE
WARNING! Disconnect the light fi xture
from the power supply system.
Maintenance operations must be carried
out by expert personnel only. These
operations involve:
• Cleaning the safety shield and external
structure to remove any material which
could negatively affect performance:
(with the appliance closed) use only clean
water and a sponge (do not use
high-pressure water jets or other
cleaning products).
• Checking that the appliance is securely
fastened to the support (once a year).
During annual inspection operations,
check the painted surfaces for signs of
damage such as blistering or cracking.
Should any such damage be found,
intervene immediately to restore the
paintwork. Contact Neri SpA for
indications and materials to be used for
retouching the paintwork.
PHOTOBIOLOGICAL RISK
The luminaire should be positioned so
that prolonged staring into the luminaire
at a distance closer than 1,85m [6' 3/4"]
(ST version) - 9,49m [31' 1 2/4"] (PR
version) - 8,25m [27' 3/4"] (RGBW
version).
RISK OF ELECTRIC SHOCK
·
·